English
Language : 

ECR2025B Datasheet, PDF (1/1 Pages) Energizer – Industry Standard Dimensions
PRODUCT DATASHEET
1-800-383-7323 USA/CAN
www.energizer.com
ENERGIZER CR2025
Industry Standard Dimensions
mm (inches)
This Battery has Underwriters
Laboratories component Recognition
Classification:
Chemical System:
Designation:
Nominal Voltage:
Typical Capacity:
Typical Weight:
Typical Volume:
Max Rev Charge:
Energy Density:
Typical Li Content:
UL Listed:
Lithium Coin
Specifications
"Lithium Coin"
Lithium / Manganese Dioxide (Li/MnO2)
ANSI / NEDA-5003LC, IEC-CR2025
3.0 Volts
163 mAh (to 2.0 volts)
(Rated at 15K ohms at 21°C)
2.6 grams (0.08 oz.)
0.8 cubic centimeters (0.05 cubic inch)
1 microampere
176 milliwatt hr/g, 616 milliwatt hr/cc
0.078 grams (0.0028 oz.)
MH29980
2.50 (0.098)
2.20 (0.087)
2.18 (0.086) Ref.
1.88 (0.074) Ref.
8.00 (0.315)
Minimum
20.00 (0.787)
19.70 (0.776)
0.03 (0.001) Minimum Ref.
(Applies to top edge of gasket or
edge of crimp, whichever is higher.)
0.20 (0.008) Maximum Ref.
Permissible deflection from a flat.
Simulated Application test
Typical Performance at 21°C (70°F)
Schedule:
Typical Drains:
at 2.9V
(mA)
Load
(ohms)
Cutoff
2.0V
(hours)
Safety:
(1) KEEP OUT OF REACH OF CHILDREN. Swallowing may lead to
serious injury or death in as little as 2 hours due to chemical burns and
potential perforation of the esophagus. Immediately see doctor; have
doctor phone (202) 625-3333.
(2) Battery compartment design. To prevent children from removing
batteries, battery compartments should be designed with one of the
following methods: a) a tool such as screwdriver or coin is required to
open battery compartment or b) the battery compartment door/cover
requires the application of a minimum of two independent and
simultaneous movements of the securing mechanism to open by hand.
Screws should remain captive with the battery door or cover.
Internal Resistance Characteristics
Pulse Test at 21°C (70°F)
Continuous
0.193
15,000
845
Typical Discharge Characteristics
Load: 15K ohms - Continuous
Typical Drain @ 2.9V: 0.193 mA
Bkgnd Drain: Continuous
15K ohms
0.193 mA @2.9V
Pulse Drain: 2 seconds X 12 times/day
400 ohms
6.8 mA @2.7V
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
0
200
400
600
800 1000
3.2
3.0
2.8
2.6
2.4
2.2
2.0
1.8
0
Bkgnd
Pulse
IR
25 50 75 100 125 150
Service, Hours
Capacity, mAh
Important Notice
This datasheet contains typical information specific to products manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
120
100
80
60
40
20
0
200
Form No. EBC - 4119K
Page 1 of 1