English
Language : 

635429 Datasheet, PDF (1/1 Pages) Energizer – Rechargeable AA-2400 (HR6)
PRODUCT DATASHEET
Rechargeable AA-2400 (HR6)
Industry Standard Dimensions
(mm)
14.50
13.50
5.50
Maximum
1.00
Minimum
50.50
49.20
Classification:
Chemical System:
Designation:
Nominal Voltage:
Rated Capacity:
Typical Weight:
Typical Volume:
Jacket:
European Region
+ 44 (0) 208 920 2306
www.energizer.eu
AA
Specifications
ACCU Rechargeable
Nickel-Metal Hydride (NiMH)
IEC-HR6
1.2 Volts
2400 mAh (to 1.0 volts)
Based on 480 mA (0.2C) discharge rate
28.0 grams
8.3 cubic centimeters
Plastic Label
Internal Resistance:
The internal resistance of the cell varies
with state of charge, as follows:
Cell Charged
Cell 1/2 Discharged
30 milliohms
40 milliohms
(tolerance of ±20% applies to above values)
7.00
Minimum
Typical Discharge Characteristics
1.4
1.3
1.2
1.1
1.0
0.9
0
Typical Performance at 21ºC
480 mA
(0.2C)
240 mA
(0.1C)
3
6
9
12
Hours of Discharge
1.4
1.3
1.2
1.1
1.0
0.9
0.0
Typical Performance at 21ºC
4.8 A
(2.0C)
2.4 A
(1.0C)
0.5
1.0
1.5
Hours of Discharge
1.2 A
(0.5C)
2.0
2.5
AC Impedance (No Load):
The impedance of the charged cell varies
with frequency, as follows:
Frequency (Hz)
1000
Impedance (milliohms)
(Charged Cell)
12
Above values based on AC current set at 1.0 ampere.
Value tolerances are ±20%.
Operating and Storage Temperatures:
To maintain maximum performance, observe the following
general guidelines regarding environmental conditions.
Charge:
Discharge:
Storage:
Humidity:
0ºC to 40ºC
0ºC to 50ºC
-20ºC to 30ºC
65±20%
Operating at extreme temperatures,
will significantly impact battery cycle life.
Important Notice
This datasheet contains information specific to battery chargers manufactured at the time of its publication.
©Energizer Holdings, Inc. - Contents herein do not constitute a warranty.
Form No. EBC - 889960EU