English
Language : 

VS1-B2-H522-00 Datasheet, PDF (3/8 Pages) Astec America, Inc – 1000 - 2500 Watts
Common Examples
and Specifications
Case size
1 = 5 inch, 2 slot, 1500 W max 1Ø
3 = 8 inch, 4 slot, 2000 W max 1Ø
4 = 11 inch, 6 slot, 2000 W max 1Ø
6 = 5 inch, 2 slot, 1500 W max 3Ø
8 = 8 inch, 4 slot, 2500 W max 3Ø
9 = 11 inch, 6 slot, 2500 W max 3Ø
(Same for Each Slot)
Option Codes
0 = no options
1 = rear air exhaust (40°C max.)
3 = set unit for global enable
5 = options 1 & 3
USE ONLY-FOR
MODIFIED STANDARD,
CONSULT-FACTORY
Output Module Code
A = 300 W single 1 slot
B = 600 W single 1 slot
C = 900 W single 2 slots
D = 1200 W single 2 slots
E = 250 W dual 1 slot
F = 250 W triple 1 slot
G = 500 W dual 1 slot
H = 500 W triple 1 slot
K = 750 W single 1 slot
L = 1500 W single 2 slot
Output Voltage Code
0 = 2V
1 = 3.3 V
2= 5V
3 = 12 V
4 = 15 V
5 = 24 V
6 = 28 V
7 = 36 V
8 = special voltage
(consult factory)
9 = 48 V
Configuration Rules
1. Omit digits that do not apply.
2. a. Specify modules from lowest number
of outputs to highest.
b. If number of outputs are equal, specify
from highest to lowest power increments.
c. If power increments are equal, specify
from highest to lowest current.
3. All model configurations created using
this selection guide represent standard
products with standard availability and
lead times.
4. If slots are left empty, a blank panel will
be automatically installed.
Example
(more on next page):
VS 1 - K 2 - G 3 3 - 0 0 - CE
5 inch case
(2 slots available)
Slot 1
Slot 2
1: 5V @ 150A 2: 12V @ 21A
3: 12V @ 20A
No options
No paralleling
Output Current
Parallel Code
VS1 and VS6
available slots
VS3 and VS8
available slots
N
J1
VS4 and VS9
available slots
N
Parallel Codes
J1
0 = no parallel
1=1&2
2=2&3
3=3&4
4=1&2 &3
5=2&3 &4
6=1&2+3&4
7=1&2&3&4
8=3&4+5&6
9=1&2+3&4+5&6
Indicates CE compliance
J1
Output Voltage
Identification
Output Output
Voltage Voltage
Code
0
1
2
2V
3.3 V
5V
Module Identification
A (1 slot)
300 W
Single
60 A
60 A
60 A
B (1 slot)
600 W
Single
120 A
120 A
120 A
C (2 slots)
900 W
Single
180 A
180 A
180 A
D (2 slots)
1200 W
Single
240 A
240 A
240 A
E, F (1 slot)
250 W Multi
Main Output
25 A
25 A
25 A
G, H (1 slot)
500 W Multi
Main Output
50 A
50 A
50 A
K (1 slot)
750 W
Single
150 A
150 A
150 A
L (2 slots)
1500 W
Single
300 A
300 A
300 A
3
12 V
25 A
50 A
4
15 V
20 A
40 A
5
24 V
12.5 A
25 A
75 A
60 A
37.5 A
100 A
80 A
50 A
10.5 A
8.3 A
5.3 A
21 A
16.6 A
10.5 A
62.5 A
50 A
31.2 A
125 A
100 A
62.4 A
6
28 V
10.7 A
21.4 A
32.1 A
42.8 A
4.5 A
9A
7
36 V
8.3 A
16.6 A
24.9 A
33.2 A
N/A
N/A
9
48 V
6.3 A
12.5 A
18.75 A
25 A
N/A
N/A
26.7 A
20.8 A
15.6 A
53.4 A
41.6 A
31.2 A
Note: Increments of current not shown can be achieved by paralleling modules (add currents of each module selected).
Auxiliary Output Table: Output(s) 2 and/or 3 of Module
Voltage
Identification
Output
Voltage
Code
Output
Voltage
Module Identification
E
250 W Dual
Aux. Output
F
250 W Triple
Aux. Output
G
500 W Dual
Aux. Output
H
500 W Triple
Aux. Output
0
2V
10 A
5A
20 A
10 A
1
3.3 V
10 A
5A
20 A
10 A
2
5V
10 A
5A
20 A
10 A
3
12 V
10 A
5A
20 A
10 A
4
15 V
10 A
5A
20 A
10 A
5
24 V
5A
2.5 A
10 A
5A
6
28 V
5A
2.5 A
10 A
5A
3
Technical Support: (888) 41-ASTEC or (407) 241-2752
Americas: (760) 930-4600
Europe (UK) 44 (1384) 842-211
Asia (HK) 852-2437-9662
69-825-410 Rev C