TLP150 Datasheet, PDF (3/4 Pages) Emerson Network Power – 150 W on main channel with only 200 LFM
Embedded Power for
Business-Critical Continuity
Ordering Information
Output
Voltage
Min
12 V
0A
24 V
0A
36 V
0A
48 V
0A
Output Currents
Max (free air)(1, 4) Max (forced air) (2,4)
8.4 A
12.5 A
4.2 A
2.7 A
2.1 A
6.3 A
4.2 A
3.2 A
Ripple (3)
120 mV
240 mV
360 mV
480 mV
Total
Regulation
±3.0%
±3.0%
±3.0%
±3.0%
Mo�d�e��l� N�u�m�b�e��r�s� (9, 10)
TLP150R-96S12J
TLP150R-96S24J
TLP150R-96S36J
TLP150R-96S48J
Notes
1 Free air convection. Maximum continuous output power not to exceed 100 W.
Refer to Figure 1 for the derating curve.
2 200 LFM forced air cooling from the ac input side. Maximum continuous output
power not to exceed 150 W.
3 Figure is peak-to-peak for room temperature rating. Output noise measurements
are made across a 20 MHz bandwidth using a 6 inch twisted pair, terminated with
a 10 µF tantalum capacitor and a 0.1 µF ceramic capacitor.
4 CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements. For optimum reliability no part of the heatsink
should exceed 115 °C and no semi-conductor case temperature should exceed
120 °C.
5 No external filtering required during conducted emissions testing but some
applications may require additional filtering to achieve system compliance.
Compliance with radiated EMI specifications may require mounting in a suitable
enclosure.
6 This product is only for inclusion by professional installers within other equipment
and must not be operated as a stand alone product.
7 Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G
8 Replace the ‘J’ at the end of the model number with ‘FJ’ when the optional
standby output and/or remote ON/OFF control is required
e.g. TLP150R-96S12FJ.
9 12 V (fan) present when main output is present. An optional 5 Vsb (standby)
output is available whenever ac input is present, regardless of remote ON/OFF
signal status.
10 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.The ‘Y’
suffix indicates TSE RoHS 5/6 (non Pb-free) compliant versions may be available
on special request, please contact your local sales representative for details.­
11 NOTICE: Some models do not support all options. Please contact your local
Emerson Network Power representative or use the on-line model number search
tool at http://www.PowerConversion.com.
12 Power good signal required 100 mA load on the main output (check with
engineering on all models).
DERATING CURVE Output Power (Watts)
150 W
100 W
200 LFM (1.0 m/s)
FORCED AIR COOLING
NATURAL CONVECTION COOLING
75 W
50 W
0W
0 C 10 C 20 C 30 C 40 C 50 C 60 C 70 C
Figure 1: Derating Curve
Outline Dimensions
5.000 (127.00)
4.550 (115.57)
Rev.1.08.09_146
TLP150
 of 4
J1 1
Neutral
Live
J2
Ground/Earth
ø0.156 (4 Places)
Dimensions in Inches (mm)
J3
1
FAN 1
J4
1
R88
0.225 (5.72)
Figure 2: Mechanical Drawing
Trimmer Adjust
Output Voltage
1
J301
Total Height
1.250 (31.75)