AVQ100-36S3V3 Datasheet, PDF (3/15 Pages) Emerson Network Power – Input under voltage lockout
AVQ100-36S3V3 DC-DC Converter
3/15
Parameter
Output voltage temperature
regulation
Total output voltage range
Output voltage ripple and noise
Operating output current range
Output DC current-limit inception
Reverse current-limit while enabled
Reverse current-limit while disabled
Vout pre-bias level
Output capacitance
50% ~ 75% ~ 50%
Io,max, 0.1A/µs
Dynamic
response
Settling time
50% ~ 75% ~ 50%
Io,max, 1A/µs
Turn-on
transient
Settling time
Rise time
Turn-on delay time
Output voltage
overshoot
100% load (24Vin)
50% load (24Vin)
100% load (48Vin)
50% load (48Vin)
Min. Typ. Max. Unit
Notes & Conditions
0.02
%/°C
3.25 3.30
3.35
V
Over sample, line, load,
temperature & life
Figure 2
40
70
mVpp
20MHz bandwidth; Figure 14
0
25
A
Hiccup: auto-restart when
27.5
35
A
over-current condition is removed
Negative current drawn from
0.5
1.0
2.0
A
output
Negative current drawn from
0
10
50
mA
output
90
%Vo
470
470
10000 µF
High frequency and low ESR is
recommended
Dynamic characteristics
Figure 4
150
mV Test condition: 25°C, nominal
input voltage, see Figure 10
100
µs
Recovery to within 1% Vo,nom
Figure 5
180
mV Test condition: 25°C, nominal
input voltage, see Figure 10
200
µs
Recovery to within 1% Vo,nom
10
30
ms
Full load, Figure 6
5
10
ms
0
%Vo
Efficiency
90
92
90.5
90
%
Figure 1
%
Figure 1
Figure 1
Figure 1
http://www.emersonnetworkpower.com.cn