English
Language : 

LPT60 Datasheet, PDF (2/3 Pages) List of Unclassifed Manufacturers – Universal input, Remote sense on main output, Low output ripple, Overvoltage protection
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
Electromagnetic
susceptibility:
Humidity:
0° to 50°C ambient derate each output at 2.5% per degree
from 50° to 70°C, -20°C startup
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Vibration:
Storage temperature:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell
at four major resonances 0.75G peak 5 Hz to 500 Hz,
operational
-40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated:
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Model
Number
LPT62-M
Output
Voltage
+5V
+12V
-12V
Minimum
Load
0.7A
0.3A
0A
Maximum Load
with Convnection
cooling
7A
3A
0.7A
Maximum Load
with 30CFM
Forced Air
8A
3.5A
1A
LPT63-M
+5V
+15V
-15V
0.7A
0.3A
0A
7A
2.8A
0.7A
8A
3.3A
1A
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
Peak Load1
10A
6A
1.5A
10A
4A
1.5A
Regulation2
±2%
±5%
±5%
±2%
±5%
±5%
Ripple P/P (PARD)3
50mV
120mV
120mV
50mV
150mV
150mV
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF in parallel with a 0.1μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
Rev. 06.15.07
LPT60-M Series
2 of 3