English
Language : 

LPT25 Datasheet, PDF (2/3 Pages) Astec America, Inc – 25 Watts
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Operating temperature:
Electromagnetic
susceptibility:
Humidity:
0° to 50°C ambient derate each output at 2.5% per degree
from 50° to 70°C, -20°C start up.
Designed to meet IEC 801, -2, -3, -4, -5, -6, Level 3
Operating; non-condensing 5% to 95%
Vibration:
Three orthogonal axes, sweep at 1 oct/min, 5 min. dwell
at four major resonances 0.75G peak 5 Hz to 500 Hz,
operational
Storage temperature:
-40° to 85°C
Temperature coefficient: ±.04% per °C
MTBF demonstrated:
>550,000 hours at full load and 25°C ambient conditions
Ordering Information
Model
Number
LPT22(-T)
Output
Voltage
5V
12V
-12V
Minimum
Load
0.3A
0.1A
0A
Maximum Load
with Convnection
cooling
3A
1.5A
0.5A
Maximum Load
with 30CFM
Forced Air
4A
2A
0.7A
Peak Load1
5A
3A
1A
Regulation2
±2%
±5%
±5%
Ripple P/P (PARD)3
50mV
120mV
120mV
LPT23(-T)
LPT24(-T)
LPT25(-T)
5V
12V
-12V
5V
12V
-5V
5V
15V
-15V
0.4A
0A
0A
0.3A
0.1A
0A
0.3A
0.1A
0A
4A
0.5A
0.5A
3A
1.5A
0.5A
3A
1.5A
0.5A
5A
0.7A
0.7A
4A
2A
0.7A
4A
2A
0.7A
6A
±2%
1A
±5%
1A
±5%
5A
±2%
3A
±5%
1A
±5%
5A
±2%
2A
±5%
1A
±5%
50mV
120mV
120mV
50mV
120mV
50mV
50mV
150mV
150mV
1. Peak current lasting <30 seconds with a maximum 10% duty cycle.
2. At 25°C including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10 μF in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Minimum Loads are required.
5. (-T) indicates Terminal Block option for input and output (instead of Molex type).
40W
Output 30W
Power 25W
(Watts) 20W
10W
Power Derating Curve
30 CFM Forced Air Cooling
Natural
Convection
Cooling
20W
12.5W
0W
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
TA – Ambient Temperature – °C
Rev. 02.05.07
LPT25 Series
2 of 3