English
Language : 

LDO10C Datasheet, PDF (2/4 Pages) Artesyn Technologies – Single Output 10 A DC-DC C Class Non-Isolated DC-DC Converter
Embedded Power for
Business-Critical Continuity
Environmental Specifications
Thermal performance
See Note 5
Operating ambient
Non-operating ambient
Protection
Short-circuit
Overvoltage protection
Recommended System Capacitance
Input
See Note 6
Output
See Note 7
-40 °C to +85 °C
-40 °C to +125 °C
Hiccup, non-latching
Hiccup, non-latching
0 μF
0 μF
Ordering Information
Output
Power
Input
(Max.)
Voltage
50W
3-13.8 Vdc
50W
3-13.8 Vdc
50W
3-13.8 Vdc
Output
Voltage
0.59-5.1 V
0.59-5.1 V
0.59-5.1 V
Output
Current
(Min.)
0A
0A
0A
Output
Current
(Max.)
10 A
10 A
10 A
Efficiency
(Typical)
94%
94%
94%
Regulation
Line Load
±0.2% ±0.5%
±0.2% ±0.5%
±0.2% ±0.5%
Model
Number (3,5)
LDO10C-005W05-VJ
LDO10C-005W05-HJ
LDO10C-005W05-SJ
Rev. 09.03.08
LDO10C
2 of 4
Part Number System with Options
Product Family
LDO
Product Family
LDO = LDO Series
Rated Output
Current
10
Rated Output
Current
10 = 10 Amp
Performance
C
Performance
C = Cost
Optimized
Input Voltage
00
Input Voltage
00 = 3-13.8 V
01 = 4.5-13.8V
Number of Pins
Type of Output
5W
Type of Output
5W = 5 Pins and
Wide Output
Output Voltage
05
Output Voltage
05 = 0.59-5.1 V
Mounting Option Custom Option
RoHS Compliance
V
X
Mounting Option
V = Vertical
H = Horizontal
S = Horizontal SMT
VS = Vertical SMT
Custom Option
J
RoHS Compliance
J = Pb free (RoHS
6/6 compliant)
Output Voltage Adjustment of the LDO10C Series
The ultra-wide output voltage trim range offers major advantages to users who select the
LDO10C series. It is no longer necessary to purchase a variety of modules in order to cover
different output voltages. The output voltage can be trimmed in a range of 0.59-5.1 Vdc.
When the LDO10C converter leaves the factory, the output has been adjusted to the default
voltage of 0.59 V.
Notes:
1. Measured as per recommended system capacitance. See Technical Reference Note.
2. di/dt = 10 A/μs, Vin = Nom, Tc = 25 °C, load change = 0.50 lo to full lo and full lo to 0.50.
3. External input fusing is recommended.
4. Additional part numbers may be available with different output voltages.
5. Airflow dependent, 100 LFM minimum required.
6. No capacitors needed for ripple current stability.
7. No capacitors needed for stability.
8. TSE RoHS 5/6 (non Pb-free) compliant versions may be available on special request,
please consult your local sales representative for details.
9. NOTICE: Some models do not support all options. Please contact your local Emerson
Network Power representative or use the on-line model number search tool at http://