English
Language : 

EXA40 Datasheet, PDF (2/3 Pages) Artesyn Technologies – 40W High Efficiency DC/DC Converters
EXA40 Series
Single output
DC-DC CONVERTERS 40 W High Efficiency DC-DC Converters
2
For the most current data and application support visit www.artesyn.com/powergroup/products.htm
INPUT
VOLTAGE
11,12) 18-36 Vdc
18-36 Vdc
18-36 Vdc
18-36 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
36-75 Vdc
OUTPUT
VOLTAGE (2)
1.5-2.0 V
2.5-3.0 V
3.0-3.6 V
4.5- 5.5 V
1.5-2.0 V
2.5-3.0 V
3.0-3.6 V
4.5 -5.5 V
NOMINAL
OUTPUT VOLTAGE
1.8 V
2.75 V
3.3 V
5.0 V
1.8 V
2.75 V
3.3 V
5.0 V
OUTPUT
CURRENT (MAX.)
8.0 A
8.0 A
8.0 A
8.0 A
8.0 A
8.0 A
8.0 A
8.0 A
TYPICAL
EFFICIENCY
84%
87%
88%
90%
84%
86%
88%
91%
MODEL
NUMBER (1,3,11,12)
EXA40-24S1V8J
EXA40-24S2V75J
EXA40-24S3V3J
EXA40-24S05J
EXA40-48S1V8J
EXA40-48S2V75J
EXA40-48S3V3J
EXA40-48S05J
Notes
1 True latching OVP is available as an option. Please add the suffix ‘-V’ to the
model number, e.g. EXA40-24S1V8-VJ. Additional alphanumeric suffixes
maybe added to indicate minor modifications not affecting the safety
approvals.
2 Gauranteed minimum output voltage range.
3 Latching OVP response time is 1 ms (typical). OVP latch is reset by
toggling remote ON/OFF or by recycling the input voltage.
4 Figures are percentage of minimum input voltage.
5 Rshort ≤20 mΩ.
6 TVS spec : 6V8 @ 10 mA, 10V5 @ 57 A
4V1 @ 1 mA, 7V3 @ 50 A
7 Maximum continuous output power.
40 Watts for S05J models
26.4 Watts for S3V3J models
22 Watts for S2V75J models
14.4 Watts for S1V8J models.
8 User must provide recommended fuses in order to comply with safety
approvals.
9 Maximum temperature on components Q100, Q102 and Q103 not to
exceed 120 °C. See Application Note 101 for details.
10 For continuous operation below 88%, minimum input voltage trimming up
>5% is not recommended on the 24S05J and 48S05J models.
11 The ‘J’ suffix indicates that these parts are Pb-free (RoHS 6/6) compliant.
TSE RoHS 5/6 (non Pb-free) compliant versions may be available on
special request, please contact your local sales representative for details.
12 NOTICE: Some models do not support all options. Please contact your
local Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
CAUTION: Hazardous internal voltages and high temperatures.
Ensure that unit is not user accessible.
EXTERNAL OUTPUT TRIMMING (10)
All models can be externally trimmed by
using the method shown below.
6
TRIM
DOWN
8
8
TRIM
UP
7
6
RTD
10K
TRIMPOT
8
10K
RTU
7
DERATING CURVE
Output Power (%)
100%
EXA40-24S05
All other Models
75%
50%
25%
27.5%
0%
-40°C -30°C-20°C -10°C 0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C 80°C 90°C 100°C
AMBIENT TEMPERATURE (°C)
Figure 1: Natural Convection (0.1m/s) Typical derating, See Application Note.
File Name: exa40.pdf Rev (02): 09 Dec 2005