English
Language : 

DS450DC-3_09 Datasheet, PDF (2/4 Pages) Emerson Network Power – 450 - 550 Watts Distributed Power System
Embedded Power for
Business-Critical Continuity
Logic Control
PS_ON/L:
(Power supply enable)
VIN_GOOD/H (Input OK):
POK/H (Output OK):
TACH_1:
PS_KILL:
Digital Control:
The power supply output will be enabled when this signal is pulled low (< 0.8 V).
HIGH = Output V1 OFF
LOW = Output V1 ON
Active High signal asserted when the input voltage rises above the min input
voltage specified.
This signal is internally pulled up through 4.7 K ohms to the 3.3 V housekeeping
voltage.
Active High signal asserted when the output is within regulation. This signal is
internally pulled up through 1.0 K ohms to the 3.3 V housekeeping voltage.
This open collector signal generates two pulses per each fan revolution. This
signal is eternally pulled up to the housekeeping voltage.
This signal will cause the output to shut down when drive high (> 24 V) or left
floating. The PS_KILL will cause the output to latch off and requires recycle of
PS_ON or DC input to reset.
PMBus - I2C compliant
Rev. 10.13.09_79
DS450DC/DS550DC
 of 4
Environmental Specifications
Operating temperature:
-10 °C to 50 °C
Storage temperature:
Altitude, operating:
-40 °C to +70 °C
10,000 ft.
Electromagnetic
- EN61000-3-2, -3-3
susceptibility / Input transients: - EN61000-4-2, 4.3, 4-4, -4-5, 4-11 Level
- EN55024:1998
RoHS & lead-free compliant (no tantalum caps.)
Humidity:
20 to 90% RH, non-condensing
Shock and vibration specificatons complies with Astec Std. Specifications, Q3205
MTBF (observed):
500K Hrs at 80%, 40 °C
Ordering Information
Output
DS450DC-3
DS450DC-3-002
DS550DC-3
DS550DC-3-003
Nominal Output
Voltage Set Point
12.0 Vdc
3.3 Vsb
12.0 Vdc
3.3 Vsb
12.0 Vdc
3.3 Vsb
12.0 Vdc
3.3 Vsb
Set Point
Tolerance
± 0.2%
± 1%
± 0.2%
± 1%
± 0.2%
± 1%
± 0.2%
± 1%
Total
Regulation
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
+5 / -3%
+5 / -4%
Minimum
Current
0A
0A
0A
0A
0A
0A
0A
0A
Maximum
Current
37.0 A
3.0 A
37.0 A
3.0 A
45.0 A
3.0 A
45.0 A
3.0 A
*Over current latches off if overcurrent lasts over 1 second, otherwise it is auto recovery.
*For 5 Vsb, consult marketing.
Output Ripple
P/P
Over Current
Options
120 mV
60 mV
39.5 - 44.4%
4.9 A Avg, 7 A max
Standard
120 mV
60mV
39.5 - 44.4%
4.9 A Avg, 7 A max
Reverse
Air
120 mV
60 mV
48.0A - 54.0A
4.9 A Avg, 7 A max
Standard
120 mV
60 mV
48.0A - 54.0A
4.9 A Avg, 7 A max
Reverse
Air