NTS350 Datasheet, PDF (1/3 Pages) Astec America, Inc – 350 Watts | |||
|
Embedded Power for
Business-Critical Continuity
NTS350 Series
350 Watts
Total Power:
Input Voltage:
# of Outputs:
200 - 350 Watts
85 - 264 VAC
120 - 300VDC
Single
Rev. 11.24.08
NTS350 Series
of 3
Special Features
⢠Active power factor correction
⢠IEC EN6100-3-2 compliance
⢠Remote sense
⢠Power fail and remote inhibit
⢠Single wire current sharing
⢠Built-in EMI filter
⢠Low output ripple
⢠5V standby
⢠12V fan output
⢠Overvoltage protection
⢠Overload protection
⢠Thermal overload protection
⢠DC power good
⢠Built in OR-ing diode / FET
⢠Optional fan cover (-CF suffix)
Safety
⢠TUV
⢠UL
⢠CSA
⢠NEMKO
⢠AUSTEL
⢠CB
⢠CE
60950
0950
60950
60950
60950
Certificate and report
Mark (LVD)
Electrical Specifications
Input
Input raÂnge
85 - 264 VAC (wide range)
Frequency
47-440 Hz
Inrush current
38A max., cold start @ 25°C
Efficiency
EMI filter
Safety ground leakage
current
85% typical at full load
FCC Class B conducted and radiated; CISPR22 Class B conducted and radi-
ated; EN55022 Class B conducted and radiated; VDE0878PT3 Class B con-
ducted and radiated.
<0.5mA @ 50/60 Hz, 264 VAC input
Output
Maximum power
200W for convection; 350W with 30CFM forced air
Adjustment range
Standby output
Fan output
Hold-up time
±5%
5V @ 2A regulated, ±5%
12 V @ 1A, -5 %, +7%, 0.5A for -CF version
20 ms @ 350 W load, 115 VAC nominal line at factory voltage setting
Overload protection
Short circuit protection on all outputs. Case overload protected @ 115-
130% above peak rating
Overvoltage protection 20-35% above nominal output
|
▷ |