English
Language : 

NLP250MEDICAL Datasheet, PDF (1/4 Pages) Emerson Network Power – Active PFC and EN61000-3-2 compliant
Embedded Power for
Business-Critical Continuity
NLP250 Medical
Series
Single output
RoHS
Rev.09.10.07
NLP250 Medical Series
1 of 4
Total Power: 250W
Input Voltage: 85 - 264VAC
# of Outputs: Single
Special Features
• Active PFC and
EN61000-3-2 compliant
• 250 W on main channel with
forced air
• Low profile fits 1U applications
• U-Channel for maximum
thermal performance
• Optional cover (CJ suffix)
• 5 V standby output
• 12 V fan output
• Integrated control and monitor-
ing features
• Compliance to EN55022-B
conducted noise standard
• RoHS compliant
• 2 year warranty
Safety
VDE0750/EN60950
IEC950/IEC60601-1
File No. 1040100-3336-0210
UL60601-1
File No. E135734
Certificate No. 40014041
CB Ref DE1-32468
Electrical Specifications
Input
Input voltage range
Universal input
85-264 Vac
Input frequency range
47-63 Hz
Input surge current
264 Vac (cold start)
40 A max.
Safety ground leakage current 264 Vac, 50 Hz
150 μA
Input current
120 Vac @ 250 W
230 Vac @ 250 W
2.78 A rms
1.36 A rms
Input fuse
UL/IEC127
T6.3 AH, 250 Vac In live and neutral
Output
Maximum power
Total regulation
(line and load)
Turn-on delay
200 LFM fored air
250 LFM with cover
Main output
Auxiliary outputs
@ 120 Vac Input
250 watts
±2.0%
±5.0%
2.0 s max.
Transient response
Temperature coefficient
Overvoltage protection
Short circuit protection
Minimum output current
Main output
50-100%
step at 0.5 A/μs
Main output
Cyclic operation
Singles
5.0% or 250 mV
max. dev., 1 ms max.
recovery to 1%
±0.02%/°C
115%, ±5%
Continuous
0A
Auxiliary outputs
(See Note 8)
5 Vsb
12 V (fan)
5 V @ 1.0 A
12 V @ 0.3 A
All specifications are typical at nominal input, full load at 25°C unless otherwise stated