English
Language : 

NLP150L Datasheet, PDF (1/3 Pages) Artesyn Technologies – LOW TO MEDIUM POWER AC/DC POWER SUPPLIES
NLP150L Series
Single and triple outputs
LOW TO MEDIUM POWER AC/DC POWER SUPPLIES 110-150 W AC/DC Universal Input Switch Mode Power Supplies 1
• 90 Vac to 264 Vac universal input range
• Provides low voltage outputs of 3.3 V
• EN61000-3-2 compliant
• Overvoltage and short circuit protection
• Power fail detection
• Current sharing (on VA and VB)
• 3.8 x 6.8 x 1.26 inches
• UL, CSA and VDE safety approvals and CE-marked to LVD
• Compliance to EN55022-B conducted noise standard
• Compliance to EN55022-A radiated noise standard
• Meets all applicable and relevant immunity standards
EN61000-4-2, -3, -4, -5 and -6
• Available RoHS compliant
The NLP150L series of 150 Watt ac-dc open-frame power supplies are available with
single, triple or quad outputs. The single and triple output versions described in this
datasheet are housed in a 3.8 x 6.8 x 1.26 inch package. All NLP150L series power
supplies are harmonic current corrected to meet the EN61000-3-2 standard, and support
current sharing. The power supplies are designed for use in 1U shelves or boxes, and are
primarily intended for networking applications that have a heavy logic content, such as
access concentrators, midrange routers, LAN switches and shared media hubs.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
Patent No. 5600546 and 5652700
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Total regulation
(Line and load)
Main output
Auxiliary outputs
±2.0%
±5.0%
Turn-on delay
@ 120 Vac Input
2.0 s, max.
Transient response
Main output
5.0% or 250 mV
75% to 100% max. dev., 1 ms max.
step at 0.1 A/µs
recovery to 1%
Temperature coefficient
±0.02%/°C
Overvoltage protection Main outputs
125%, ±10%
Short circuit protection Cyclic operation
Continuous
Minimum output current Singles and multiple
See table
INPUT SPECIFICATIONS
Input voltage range
(See Note 12)
Universal input
90-264 Vac
Input frequency range
47-63 Hz
Input surge current
264 Vac (cold start)
40 A max.
Safety ground
leakage current
264 Vac, 60 Hz
0.99 mA
Input current
120 Vac @ 150 W
230 Vac @ 150 W
1.95 A rms
1.10 A rms
Input fuse
UL/IEC127
F3.15A H, 250 Vac
EMC CHARACTERISTICS (10)
Conducted emissions
Radiated emissions
Harmonic current
emission correction
ESD air
ESD contact
EN55022, FCC part 15
EN55022, FCC part 15
EN61000-3-2
EN61000-4-2
EN61000-4-2
Level B
Level A
Compliant
Level 3
Level 3
EMC CHARACTERISTICS (continued) (10)
Surge
Fast transients
Radiated immunity
Conducted immunity
EN61000-4-5
EN61000-4-4
EN61000-4-3
EN61000-4-6
Level 3
Level 3
Level 3
Level 3
GENERAL SPECIFICATIONS
Hold-up time
120 Vac @ 60 Hz
20 ms @ 150 W
Efficiency (See Note 13) 120 Vac @ 150 W
73% typical
Isolation voltage
Input/output
Input/chassis
3000 Vac
1500 Vac
Approvals and
standards pending
EN60950, VDE0805, IEC950
UL1950, CSA C22.2 No. 950
Weight
540 g (19 oz)
MTBF (@ 25 °C)
MIL-HDBK-217F 350,000 hours min.
Bellcore
800,000 hours min.
ENVIRONMENTAL SPECIFICATIONS (8)
Thermal performance
Operating ambient,
(See derating curve)
0 °C to +50 °C
Non-operating
-40 °C to +85 °C
50 °C to 70 °C ambient,
convection cooled
Derate to
50% load
0 °C to 50 °C ambient,
convection cooled
110 W
0 °C to 50 °C ambient,
300 LFM forced air
150 W
Peak (0 °C to +50 °C)
(See Note 3)
Relative humidity
Non-condensing
5% to 95% RH
Altitude
Operating
Non-operating
10,000 feet max.
30,000 feet max.
Vibration (See Note 6) 5-500 Hz
2.4 G rms peak
Shock
per MIL-STD-810E
516.4 Part IV
File Name: nlp150lst.pdf Rev (03): 08 Nov 2005