English
Language : 

NFS110_09 Datasheet, PDF (1/5 Pages) Emerson Network Power – Single & Quad output
Embedded Power for
Business-Critical Continuity
NFS110 Series
Single & Quad output
Rev. 11.2.09_69
NFS110 Series
1 of 5
Total Power: 80 - 110 W
Input Voltage: 85 - 264 Vac
120 - 370 Vdc
# of Outputs: Single, quad
Special Features
• 7.0 x 4.25 x 1.8 inch package
• Overvoltage and short circuit
protection
• 110 W with 20 CFM
• Adjustable outputs
• EN55022, EN55011 conducted
emissions level B
• UL, VDE and CSA safety
approvals
• CE mark
• Available RoHS compliant
• 2 year warranty
Safety
• VDE0805/EN60950/
• IEC950/IEC1010
File No. 10401-3336-0213
• Licence No. 4001467 7
• UL1950 File No. E132002
• CSA C22.2 No. 950
File No. LR41062C
Electrical Specifications
Output
Voltage adjustability:
Line regulation:
Overshoot/undershoot:
Temperature coefficient:
Overvoltage protection:
Output power limit:
Minimum output current:
Short circuit protection:
+5.1 V o/p on multi’s
5.1 V single output
12 V single output
15 V single output
24 V single output
LL to HL, FL
All outputs on all units
At turn-on
All outputs
Multi o/p 5.1 V only
5.1 V single output
12 V single output
15 V single output
24 V single output
Primary power limited
(See Note 13)
Burst mode operation
3.0%
3.0%
12 - 14 V
15 - 18 V
24 - 30 V
±0.1% max.
0%
±0.02%/°C
6.25 V ± 0.75 V
6.25 V ± 0.75 V
15.75 V ± 1.0 V
22 V ± 1.5 V
33 V ± 2.5 V
Pin max. 160 W
Pout min. 110 W
0A
Input
Input voltage range:
Input frequency range:
Input surge current:
Safety ground leakage current:
230 Vac
110 Vac, 50 Hz
230 Vac, 50 Hz
85 - 264 Vac
120 - 370 Vdc
47 - 440 Hz
35 A
0.2 mA, max.
0.4 mA, max.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated