Embedded Power for
Business-Critical Continuity
LPS50-M Series
60 Watts
Total Power:
Input Voltage:
# of Outputs:
55 - 60 Watts
90 - 264 VAC
127 - 300 VDC
Single
Rev. 1.08.09_149
LPS50-M Series
of 3
Special Features
⢠Medical Safety Approvals
⢠Universal input
⢠Less than 1U high
⢠2â x 4â footprint
⢠Remote sense
⢠Overload and short circuit
protection
⢠Adjustable output voltage
⢠High efficiency
⢠High MTBF
⢠Built in EMI filter
(CISPR 22 Class B)
⢠LED power good indicator
⢠Input power < 74 watts
⢠Complies with EN61000 -3-2
⢠UL Class I approved
⢠LPX50 enclosure kit available
⢠Dual AC fuses
Safety
⢠UL:
⢠CSA:
⢠VDE:
⢠CE:
UL 60601-1
CSA-C22.2 No. 601.1-M90
EN60601-1
LVD & EMC
Electrical Specifications
Input
Input raÂnge:
90 - 264 VAC (wide range) 127-300 Vdc
Frequency:
47-440 Hz
Inrush current:
< 60 A peak @ 230 VAC, cold start @ 25°C
Input power:
Efficiency:
< 74 Watts
80% - 85% typical at full load
EMI/RFI:
FCC Class B conducted; CISPR 22 Class B conducted; EN55022 Class B
conducted, VDE0878PT3 Class B conducted
Safety ground leakage 275uA @ 50/60 Hz; 264 VAC input
current:
Output
Maximum power:
60W for convection (LPS52, 55 W)
Adjustment range:
±20% minimum
Hold-up time:
10/20 ms 115/230 VAC input line
Overload protection:
Short circuit protection on all outputs. Case overload protected @
110-160% of normal rating
Overvoltage protection: 30-50% above nominal output
Remote sense:
Compensatesd for 0.5 V lead drop max. Will operate without remote sense
connected. Reverse connection protected.
|
▷ |