LPS172 Datasheet, PDF (1/3 Pages) Emerson Network Power – Active power factor correction | |||
|
Embedded Power for
Business-Critical Continuity
LPS170 Series
175 Watts
Total Power:
Input Voltage:
# of Outputs:
100 - 175 Watts
85-264 VAC
120-300 VDC
Single
Rev. 08.04.09_101
LPS170 Series
of 3
Special Features
⢠Active power factor correction
⢠IEC EN61000-3-2 compliance
⢠Wide Range Adjustable output
Remote sense on main output
⢠Single wire current sharing
⢠Power fail and remote inhibit
⢠Built-in EMI filter
⢠Low output ripple
⢠Overvoltage protection
⢠Overload protection
⢠Thermal overload protection
⢠DC power good
⢠5 Vstandby output
⢠12 V Aux output
⢠Optional cover (-C suffix)
Safety
⢠VDE
⢠UL
⢠CB
⢠CSA
⢠CE
⢠NEMKO
0805/EN60950
(IEC950)
UL1950
Certificate and report
CSA 22.2-234 Level 3
Mark (LVD)
EN 60950/EMKO-TUE
Electrical Specifications
Input
Input raÂnge:
85-264 VAC; 120-300 VDC
Frequency:
47-63 Hz
Inrush current:
38 A max, cold start @ 25°C
Efficiency:
EMI filter:
75% typical at full load
FCC Class B conducted
CISPR 22 Class B conducted
EN55022 Class B conducted
VDE 0878 PT3 Class B conducted
Power Factor:
0.99 typical
Safety ground
leakage current:
Output
Maximum power:
1.0 mA @ 50/60 Hz, 264 VAC input
110 W convection (75 W with cover)
175 W with 30 CFM forced air
(130 W with cover)
Adjustment range:
2:1 wide ratio minimum
Standby outputs:
Hold-up time:
5 V @ 2 A regulated±5%
20 ms @175 W load at nominal line
Overload protection: Short circuit protection on all outputs.
Case overload protected @ 110-145% above peak rating
Overvoltage protection: 10% to 40% above nominal output
Aux output:
12 V @ 1 A-5 %, +10%
|
▷ |