English
Language : 

LCT43-E Datasheet, PDF (1/3 Pages) Astec America, Inc – 47 Watts
Embedded Power for
Business-Critical Continuity
LCT43-E Series
47 Watts
Total Power:
Input Voltage:
# of Outputs:
47 Watts
85 - 264 VAC
120 - 300VDC
Triple
RoHS
Rev. 8.17.06
LCT43-E Series
1 of 3
Special Features
• Totally enclosed
• Universal input
• Quick Installation
• Built-in EMI filter
• Low output ripple
• Overvoltage protection
• Overload protection
Safety
VDE 0805/EN60950
21310-3336-0003
UL
UL60950
E186249
CSA CSA 22.2-234 -950-95-M90
CB
Certificate and report
6593
CE
Mark (LVD)
Electrical Specifications
Input
Input range
Frequency
85 - 264 VAC (wide range)
120 - 300VDC
47-63 Hz
Inrush current
<20A peak @ 115VAC, <40A peak @ 230VAC cold start @ 25°C
Input current
1A max. (RMS) @ 115VAC
Efficiency
70% typical at full load
EMI filter
FCC Class B conducted and radiated; CISPR 22 Class B
conducted and radiated; EN55022 Class B conducted and
radiated
Bellcore GR-1089-core Class B conducted
Safety ground leadage <3.5 mA @ 50/60 Hz, 264 VAC input
current
Output
Maximum power
47W with 12CFM forced air
Cross regulation
±2% on output 1; ±5% on outputs 2, 3
Hold-up time
10ms @ 47W load, 100VAC input
Overload protection Short circuit protection on all outputs. Case overload protect-
ed @ 110-135% above peak rating
Overvoltage protection 5.50-6.75 VDC on main output