LCM600 Datasheet, PDF (1/6 Pages) Emerson Network Power – 600 Watts Bulk Front End | |||
|
Embedded Power for
Business-Critical Continuity
LCM600
600 Watts
Bulk Front End
Total Power: 600 W
# of Outputs: Single
Output:
3.3 to 60 V
Optional 5.0 V standby
Rev. 10.26.11_131
LCM600 Series
1 of 6
Special Features
⢠600 W output power
⢠Low Cost
⢠2.4â x 4.5â x 7.5â
⢠7.41 W/cu-in
⢠Industrial/Medical safety
⢠-40 °C to 70 °C with derating
⢠Optional 5 V @ 2 A Housekeeping
⢠High Efficiency: 89% typical
⢠Variable speed âSmart Fansâ
⢠DSP controlled front end
⢠Conformal coat option
⢠± 20% adjustment range
⢠Margin programming
⢠OR-ing FET
⢠Terminal block input option
Compliance
⢠EMI Class B
⢠EN61000 Immunity
Safety
⢠UL
60950-1
508/1598/1433
60601-1
⢠CSA
60950-1
⢠VDE
60950-1
60601
⢠China
CCC
⢠CB Scheme Report/Cert
Electrical Specifications
Input
Input raÂnge:
85 - 264 Vac (Operating)
115/230 Vac (Nominal) Input through standard IEC connector
Frequency:
Input fusing:
Inrush current:
Power factor:
Harmonics:
Input current:
Hold up time:
Efficiency:
Leakage current:
ON/OFF power switch:
47 - 440 Hz, Nominal 50/60
Internal 10 A fuses, both lines fused
⤠25 A peak, either hot or cold start
0.99 typical, meets EN61000-3-2
Meets IEC 1000-3-2 requirements
8 A RMS max input current, at 100 Vac
20 ms minimum for Main O/P, at full rated load
> 88% at full load
< 0.3 mA at 264 Vac
N/A
Power line transient:
Isolation:
MOV directly after the fuse
PRI-Chassis 2500 Vdc Basic
PRI-SEC 2500 Vdc Reinforced
SEC-Chassis 500 Vdc
LCM600Q Efficiency Without the 5 Vsb and 24 V ORing FETS
92.00
90.00
88.00
86.00
84.00
82.00
100 Vac
230 Vac
80.00
78.00
76.00
25
50
75
100
Loading %
|
▷ |