IVS_11 Datasheet, PDF (1/12 Pages) Emerson Network Power – Intelligent VS Power | |||
|
ss
w
Embedded Power for
Business-Critical Continuity
Intelligent VS Power
Up to 4920 Watts
Total Power: Up to 4920 Watts
Input Voltage: 85 - 264 Vdc
120 - 300 Vdc
# of Outputs: Up to 24
Special Features
⢠Full medical EN60601 approval
⢠Intelligent I2C control
⢠Voltage adjustment on all outputs
(manual or I2C)
⢠Configurable input and output
OK signals and indicators
⢠Configurable inhibit/enable
⢠Configurable output UP/DOWN
sequencing
⢠High power density (12 W/cu-in)
⢠Intelligent fan (speed control/
fault status)
⢠uP controlled PFC input with
active Inrush protection
⢠I2C monitor of voltage, current,
and temperature
⢠Programmable voltage, current
limit, inhibit/enable through I2C
⢠Optional extended hold-up
module (SEMI F47 compliance)
⢠Increased power density to 150%
⢠Optional conformal coating
⢠Industrial temp range (-40 ºC to
70 ºC)
⢠Uses standard iMP modules
⢠Field upgradeable firmware
⢠RoHS compliant
Safety
⢠UL
⢠CSA
⢠VDE
⢠BABT
⢠CB
⢠CE
UL60950/UL2601
CSA22.2 No. 234 Level 5
EN60950/EN60601-1
Compliance to EN 60950/
EN60601 BS 7002
Certificate and report
Mark to LVD
TM
Font: Minion Bold for VS
Minion italic for i ; size for each is the same
Created on Mac
Color: "i" 100% Blue, 50% Magenta,
0% Yellow, 0% Black
"VS" - 100% Black
Rev. 01.10.11_41
iVS Series
1 of 12
Electrical Specifications
Input
Input ran ge:
iVS1 & iVS390 - 264 Vac 1Ã; 120 - 300 Vdc
iVS6 & iVS8 170 - 264 Vac 3Ã
Frequency:
47 - 440 Hz
Inrush current:
40 A peak maximum (soft start)
Efficiency:
Up to 85% @ full case load
Power Factor:
0.99 typ. meets EN61000-3-2
Turn-on time:
AC on 1.5 sec typical, inhibit/enable 150ms typical Programmable;
50ms internal turn-on delay (Dual Output only)
EMI Filter:
CISPR 22/EN55022 Level âBâ
Leakage current:
500 µA max. @ 240 Vac; 47-63 Hz
Radiated EMI:
CISPR 22/EN55022 Level âBâ
Holdover storage:
10 ms minimum(independent of input Vac) additional 20mSEC
holdover storage with optional HUP module
(SEMI F47 compatible)
AC OK:
>5ms early warning minutes before outputs lose regulationFull cycle
ride thru (50Hz).Programmable
Harmonic distortion: Meets EN61000-3-2
Isolation:
Meets EN60950 and EN60601
Global inhibit / enable: TTL, Logic â1â and Logic â0â; configurable
Warranty:
3 years
|
▷ |