DS450DC-3 Datasheet, PDF (1/4 Pages) Emerson Network Power – Distributed Power System | |||
|
Embedded Power for
Business-Critical Continuity
DS450DC-3/
DS550DC-3
450 - 550 Watts
Distributed Power System
Distributed Power Bulk Front-End
Total Output Power: 450 - 550 Watts
+12Vdc main Output
+3.3vdc Stand-by Output
DC Input 40 - 75 Vdc
Special Features
⢠1U X 2U Form Factor
⢠10.3W / in3 (DS550)
8.4W / in3 (DS450)
⢠+12vdc Output
⢠+3.3vdc Stand-By
⢠No Minimum Load Required
⢠Hot Plug Operation
⢠N + 1 Redundant
⢠Internal ORâing Fets
⢠Active Current Sharing
⢠Built-in Cooling Fans
(40mm x 28mm)
⢠I2C Communication Interface Bus
⢠EERPOM for FRU Data
⢠Amber LED Status, Fan_Fail
⢠Green LED Status, Power Good /
DC_OK Status (VIN_GOOD)
⢠Internal Fan Speed Control
⢠Fan Fail Tach Output Signal
⢠One Year Warranty
Safety
⢠UL/cUL 60950 (UL Recognized)
⢠NEMKO+ CB Report EN60950
⢠EN60950
⢠CE Mark
⢠China CCC
DC Input
Connector input shown
Electrical Specifications
Input
Input raÂnge:
40-75 Vdc
Frequency:
Inrush current:
DC input
21A maximum
Efficiency:
EVT: 87% @ 72 Vdc; 87.4% @ 75 Vdc
Conducted EMI:
FCC Subpart J EN55022 Class A
Radiated EMI:
FCC Subpart J EN55022 Class A
Power factor:
N/A
Leakage current:
N/A No touch current required.
Hold up time:
1ms minimum
Output
Main DC voltage:
+12 V
Stand-By:
+3.3 vsb
Adjustment range:
Factory Set, no pot adjustments
Regulation:
+12 Vdc;+5%/-5%
+3.3 vsb; +5%/-5%
Over current:
See Table 1 next page
Over voltage:
+12 Vdc; 13.5 - 15 Vdc
+3.3 vsb; 3.76 - 4.30 Vdc
Under voltage:
+12 Vdc; 10.5 V - 11.0 V
+3.3 vsb; 2.77 - 3.00 Vdc
Turn-on delay :
+12v Output Rise Time
<3 seconds, EVT: 2 seconds
3 - 300 mS
Rev. 12.15.08
DS450DC/DS550DC
of 4
|
▷ |