CXE15 Series
Single output
DC-DC CONVERTERS 15 W High Efficiency DC-DC Converters
• High efficiency topology, 87% typical at 5 V
• Industry standard footprint
• Wide operating temperature, up to and exceeding 65 ˚C
(natural convection)
• 90% to 110% output trim
• No minimum load
• Overvoltage protection
• Remote ON/OFF control
• Available RoHS compliant
The CXE15 is a new high efficiency open frame isolated 15 Watt converter series
in an industry standard footprint. The CXE15 features an input voltage range of 33
Vdc to 75 Vdc and are available in output voltages of 5 V and 3.3 V. The output
voltage on each model is adjustable from 90% to 110% of the nominal value.
Typical efficiencies for the models are 87% for the 5 V and 86% for the 3.3 V. The
CXE15 series also has a remote ON/OFF capability with active high or active low
logic. Overcurrent and overvoltage protection features are included as standard.
With full international safety approval including EN60950 and cUL1950, the CXE15
reduces compliance costs and time to market.
All specifications are typical at nominal input, full load at 25 °C unless otherwise stated
1
TÜV
2 YEAR WARRANTY
SPECIFICATIONS
OUTPUT SPECIFICATIONS
Voltage adjustability
90% to 110%
Total error band
(See Note 11)
±3.5% max.
Line regulation
Low line to high line
0.1% max.
Load regulation
Full load to min. load
0.5% max.
Minimum load
0%
Overshoot
None
Undershoot
None
Ripple and noise
(See Note 1)
5 Hz to 20 MHz
70 mV pk-pk
20 mV rms
Transient response
typ. deviation
(See Note 2)
100 mV
400 µs recovery to
within total error band
INPUT SPECIFICATIONS
Input voltage range
48 Vin nominal
33-75 Vdc
Input current
No load
Remote OFF
35 mA max.
25 mA max.
Input current (max.)
(See Note 4)
0.55 A max. @ Io max.
and Vin = 33-75 Vdc
Input reflected ripple
(See Note 6)
5 mA (pk-pk) typ.
Active high remote ON/OFF
Logic compatibility
ON
OFF
(See Note 10)
Open collector ref to -input
Open circuit or >2 Vdc
<1.2 Vdc
Undervoltage lockout
Power up
Power down
33 V (typ.)
30 V (typ.)
Start-up time
(See Note 7)
Power up
Remote ON/OFF
1.5 ms (typ.)
2.5 ms (typ.)
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
Immunity:
ESD air
ESD contact
Radiated field enclosure
Conducted (dc power)
Conducted (signal)
Input transients
EN55022 (See Note 3)
EN55022 (See Note 3)
Level A
Level B
EN55022 (See Longform datasheet) Level B
EN61000-4-2 8 kV, 15 kV
EN61000-4-2 6 kV, 8 kV
EN61000-4-3 10 V/m
EN61000-4-6 10 V
EN61000-4-6 10 V
ETS 300 132-2, ETR 283
(See Note 8)
GENERAL SPECIFICATIONS
Efficiency
See table
Operational insulation Input/output
1500 Vdc
Switching frequency
Fixed
265 kHz typ.
Approvals and
standards
(See Note 5)
UL/cUL1950, EN60950
TÜV Rheinland
Material flammability
UL94V-0
Weight
12 g (0.42 oz)
MTBF
Representative model:
MIL-HDBK-217F
3,628,000 hours
48S05J @ 48 Vin, 40 °C,
100% load ground benign
BELLCORE 332
>1,500,000 hours
ENVIRONMENTAL SPECIFICATIONS
Thermal performance
(See Note 9)
Operating ambient
temperature
Non-operating
-40 °C to +65 °C
-40 °C to +120 °C
File Name: cxe15s.pdf Rev: 01 Mar 2006