English
Language : 

ALD13B50 Datasheet, PDF (1/3 Pages) Emerson Network Power – 1/16th Brick IBC Series
Embedded Power for
Business-Critical Continuity
AED/ALD13B50
1/16th Brick IBC Series
Total Power: 150 Watts
Input Voltage: 38 - 60 Vdc
Output Voltage: 12 Vdc
Rev. 06.15.09_11
AED/ALD13B50
 of 3
Special Features
• Intermediate Bus Converter
for Front End
(DPA) Distributed Power
Architecture application
• High efficiency (95% Typical)
• Industry standard package
16th Brick 0.90” x 1.30”
• High capacitive load limit on
start-up
• Output Enable Pin
• Undervoltage lockout
• Over Temperature Protection
• Meets Basic Insulation
• EU directive 2002/95/EC
compliant for RoHS
Electrical Specifications
Input
Input ra­nge:
38 V to 60 V
Efficiency:
95%@ 12 V (typical)
Over Voltage Protection:
67 V typical
Input UVLO:
33 V to 38 V
Output
Output current:
13 A max
Output Voltage over line, load
and temperature:
8.7 V to 15 V
Noise/ripple1:
180 mV (typical)
Over current limit:
Auto-restart
Over temperature protection: 110 °C minimum (autorecovery)
Switching frequency:
165 kHz
Control
Enable:
TTL compatible (positive or negative enable logic)
Isolation Voltage:
Input to Output:
2000 Vdc max
Safety
• UL, cUL:60950
• TUV: EN60950
Environmental Specifications
Operating ambient temperature range: -40 °C to +85 °C ambient
Storage temperature:
MTBF:
-55 °C to +125 °C
> 1 million hours