AD2412N3L
24 Watts
Total Power:
Input Voltage:
# of Outputs:
24 Watts
90 - 264 Vac
Single
Rev. 3.3.10_135
AD2412N3L
1 of 2
Special Features
• Universal AC input
• Fully regulated output
• EN61000-3-2 compliant
• Overcurrent and overvoltage
protection
• High efficiency
• High MTBF
• IEC320 AC input receptacle
3 pin (type C14)
• Built in EMI filter
• (CISPR 22 Class B)
• LED power good indicator
• AC input fuse
• Energy Star 2.0 & CeC approvals
• Efficiency Level V
• CE Mark EMC & LVD
• Meets K.21 Basic Surge requirement
Safety
• UL
UL 60950-1
• CSA
CSA-C22.2 no.60950
• TUV
EN/IEC60950-1
• CE Mark LVD and EMC
• CCC
Certificate
• CB
Certificate
Electrical Specifications
Input
Input ra­nge:
90 - 264 Vac (wide range)
Frequency:
47 - 63 Hz
Inrush current:
Input current:
Efficiency:
50 A maximum @ 230 Vac, cold start 25 °C
1 A maximum
82% typical
EMI/RFI:
FCC Part 15, Class B & EN55022 (CISPR 22) Class B
Safety ground
leakage current:
250 µA maximum@ 50/60 Hz, 264 Vac input
Output
Maximum Power (Po):
Hold-up time:
Overvoltage protection:
24 W
20 ms. minimum at full load @ 115 Vac, 60 Hz
28 V
Latching type, recycle AC to reset.
Overcurrent protection: Output short circuit protection auto recover
Overload protection @ 2.5 - 5A
Thermal protection:
Latching type, recycle AC to reset
Cable/connector :
DC cable with 2.5 mm I.D./ 5.5 mm O.D. center plug
DC plug center +v
DC plug outer -v
Environmental Specifications
Operating temperature: -5° to +50 °C ambient
Storage temperature:
Electromagnetic
susceptibility:
Humidity:
MTBF calculated:
-45 °C to +85 °C
Designed to meet EN61000-4-2, -4, -5, level 3;
EN61000-4-3, -6, 6v/m; EN61000-3-3
and EN61000-3-2 Class A
Operating; non-condensing 5% to 90% RH
> 850,000 hours at full load and 25 °C ambient conditions,
Telcordia SR332 Issue 1 (Method 1, Case 3)