English
Language : 

SIS6 Datasheet, PDF (1/1 Pages) ELESTA GmbH – SIS 6 Series
SIS 6 Series
Relay Key Data
- PCB Relay with forcibly guided contacts
- Protective separation between control and load curcuit
(leakage and creepage distances >8 mm)
- EN50205 type A
- Double and reinforced insulation between the contacts
- Contact mounting: SIS422 4 NO / 2 NC
- Small external dimensions
- Nominal coil power 0,66 W
- Holding coil power 0,20 W
- For railway application (EN50155) on request
Dimensions
48
16,6
Circuit Diagram (view on relay upper side)
64
63
54
53
44
43
32
31
22
21
13
14
A1
A2
SIS422
0,4 0,3
1
2 6,5 6,5 10,2 8,5 5 7 2,3
Ø1,3
4 6,5 6,5 6,5 8,5 8,7 5 2,3
[mm]
Contact Data
Contact material
AgCuNi + 0,2 µm Au
Type of contact
Single contact with notched crown
Rated switching capacity
250 VAC 6 A AC1 1500 VA
Electr. life AC 1(360 cycles / h)
>90000
Inrush current max.
30 A for 20 ms
Switching voltage range
5 to 250 VDC / VAC
Switching current range*
3 mA to 6 A
Switching capacity range*
40 mW to 1500 W(VA)
Contact resistance (as delivered) ≤100 mΩ / 6 V / 100 mA
*Guided values
Standard coils for direct current
(other voltages on request)
5
3,5 ≥0,5
133
37,5 ± 10%
9
6,3 ≥0,9 73,7
122 ± 10%
12
8,4 ≥1,2 55,8
215 ± 10%
18
12,6 ≥1,8 37,1
485 ± 10%
24
16,8 ≥2,4 29,7
860 ± 10%
48
33,6 ≥4,8 13,9 3450 ± 10%
60
42,0 ≥6,0
11,1 5400 ± 13%
110
77,0 ≥11,0
6,0 18300 ± 15%
Insulation Data
- Basic insulation
at 250 VAC
- Air and creepage distance
>4 mm
- Test voltage
2500 V / 50 Hz / 1 min
- Double or reinforced insulation
at 250 VAC
- Air and creepage distance
>5,5 mm
- Test voltage
4000 V / 50 Hz / 1 min
- Double or reinforced insulation
- Air and creepage distance
at 250 VAC
>8 mm
- Test voltage
4000 V / 50 Hz / 1 min
Test voltage contact open
1500 V / 50 Hz / 1 min
Creepage resistance
CTI 175
Pollution degree
2
Overvoltage category
III
Insulation resistance at Up 500 VDC
>100 MΩ
Additional Data
Mechanical endurance
>10 x 106 operations
Switching frequency, mechanical
15 Hz
Response time (all NO closed)
typically 15 ms
Drop-out time** (all NC closed)
typically 5 ms
Bounce time of NO contact
typically 2 ms
Bounce time of NC contact
typically 15 ms
Shock resistance 16 ms
NO > 10g
NC > 9g
Vibration resistance
NO > 10g
(10-200 Hz)
NC > 3g
Resistance to short circuiting contacts
1000 A SCPD 6 A gG / gL (pre-fuse)
Ambient temperature
-40°C to +85°C
Thermal Resistance
45 K / W
Temperature limit for coil
120°C
Weight
ca. 35 g
Mounting position
any
Type of protection
RT III
Solder bath temperature
270°C / 5 s
**without spark suppression
Tests, Regulations
Approvals
UL File E188953
Insulation class IEC 60664-1
Protection class II
Fire protection requirements
Sec. 5
250 VAC
VDE 0106
UL 94 / V0
Options, Accessories
none available
Product Key
SIS 4 2 2 24VDC
Coil voltage
Soldering tags
Number of NC contacts
Number of NO contacts
Type designation
Contact Lifetime for NO Contacts
10000
5000
1000
500
DC 1: 24V
AC 1:230V
100
50
AC 15: 230V
DC 13: 24V
10
0,1
0,5 1
Switching Current (A) →
2 3 4 5 6 7 8910
Maximal switching characteristics (DIN EN60947-5-1)
AC 1:
250 V / 6 A
AC 15: 230 V / 3 A
DC 1:
24 V / 6 A
DC 13: 24 V / 5 A / 0,1 Hz
UL 508: B300 / R300
Maximal contact load at AC 1 with 230 V:
2 contacts with 6 A each
3 contacts with 4 A each
4 contacts with 3 A each
Load Limit Curve with Direct Current
6
4
3
2
1
2
1
00,,68
0,4
0,3
0,2
0,1
0
50
100
150 200 250
Voltage (VDC) →
1) Inductive load L/R 40 ms
2) Resistive load
Excitation Voltage Range
3,0
2,5
2,0
1
1,5
1,0
2
0,5
UB
UN 0
0
20
40
60
Ambient Temperature °C →
80 100
1) Max. excitation voltage with contact load: ≤4 A
2) Min. excitation voltage (guaranteed values) without
previous operation
No heat accumulation due to intrinsic heating of
other components. Continuous duty 100%.
ELESTA GmbH, Heuteilstrasse 18, Fon:
CH - 7310 Bad Ragaz, Switzerland Fax:
+41 (0)81 303 54 00
+41 (0)81 303 54 01
© Copyright
11/2014