English
Language : 

SIP6 Datasheet, PDF (1/1 Pages) ELESTA GmbH – SIP 6 Series
SIP 6 Series
Relay Key Data
- PCB Relay with forcibly guided contacts
- Protective separation between coil/control contacts and
output contacts (>8 mm) and output contacts in one row
(>10 mm)
- EN50205 type A
- Contact mounting:SIP512 Control contacts 1 NO / 1 NC
Output contacts 4 NO
SIP422 Control contacts 2 NC
Output contacts 4 NO
- High switching power
- Nominal coil power 1,3 W
- Holding coil power 0,39 W
- For railway application (EN50155) on request
Dimensions
84,6
20
12,5
0,4
2,1 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 4,1 0,5
6,5
1
3 14 3
Ø 1,3
[mm]
2,1 25,4 5 8,5 5 6,5 5 6,5 5 6,5 5 4,1
Control Contact
Contact material
AgSnO2 + 0,2 µm Au
Rated switching capacity
250 VAC 6 A AC1 1500 VA
Electr. life AC 1(360 cycles / h)
approx.100000
Inrush current max.
15 A for 20 ms
Switching voltage range
5 to 250 VDC / VAC
Switching current range*
5 mA to 6 A
Switching capacity range*
60 mW to 1500 W(VA)
Contact resistance (as delivered)
≤100 mΩ / 6 V / 100 mA
Output Contact
Contact material
Rated switching capacity
AgSnO2
250 VAC (440 VAC) 16 A AC1 4000 VA
Electr. life AC 1(360 cycles / h)
approx.250000
Inrush current max.
60 A for 20 ms
Switching voltage range
5 to 250 VDC (480 VAC)
Switching current range*
10 mA to 16 A
Switching capacity range*
120 mW to 4000 W(VA)
Contact resistance (as delivered)
≤100 mΩ / 6 V / 100 mA
*Guided values
Standard coils for direct current
(other voltages on request)
Circuit Diagram (view on relay upper side)
63 64
53 54
43 44
63 64
53 54
43 44
33
34
12 23
11 24
33
34
12 22
11 21
SIP 512
SIP 422
A1
A2
A1
A2
Insulation Data
- Basic insulation
at 250 VAC
- Air and creepage distance
>4 mm
- Test voltage
2500 V / 50 Hz / 1 min
- Double or reinforced insulation at 250 VAC
- Air and creepage distance
>8 mm
- Test voltage
4000 V / 50 Hz / 1 min
- Double or reinforced insulation at 250 VAC
- Air and creepage distance
>10 mm
- Test voltage
5000 V / 50 Hz / 1 min
Test voltage contact open
1500 V / 50 Hz / 1 min
Creepage resistance
CTI 250
Pollution degree
2
Overvoltage category
III
Insulation resistance at Up 500 VDC
>100 MΩ
Additional Data
Mechanical endurance
>10 x 106 operations
Switching frequency, mechanical
15 Hz
Response time (all NO closed)
typically 18 ms
Drop-out time** (all NC closed)
typically 5 ms
Bounce time of NO contact
typically 8 ms
Bounce time of NC contact
typically 12 ms
Shock resistance 16 ms
NO > 10g
NC > 8g
Vibration resistance
10-200 Hz
NO > 10g
10-50 Hz
NC > 5g
50-200 Hz
NC > 3,5g
Resistance to short circuiting control contacts
1000 A SCPD 6 A gG / gL (pre-fuse)
Resistance to short circuiting output contacts
1000 A SCPD 16 A gG / gL (pre-fuse)
Ambient temperature
-40°C to +70°C
Thermal resistance
40 K / W
Temperature limit for coil
125°C
Weight
ca. 60 g
Mounting position
any
Type of protection
RT II
Solder bath temperature
270°C / 5 s
**without spark suppression
Tests, Regulations
Approvals
6
4,2 ≥0,6 218,0
27,5 ± 10%
12
8,4 ≥1,2 109,0
110 ± 10%
18
12,6 ≥1,8 72,0
248 ± 10%
24
16,8 ≥2,4 54,5
440 ± 10%
48
33,6 ≥4,8 27,2 1760 ± 10%
60
42,0 ≥6,0 21,8 2750 ± 10%
110
77,0 ≥11,0
11,8 9250 ± 13%
220 154,0 ≥22,0
5,9 37000 ± 15%
UL File E188953
Insulation class IEC 60664-1
Protection class II
Fire protection requirements
Sec. 4
250 VAC
VDE 0106
UL 94 / V0
Options, Accessories
none available
Product Key
SIP 4 2 2 24VDC
Coil voltage
Soldering tags
Number of NC contacts
Number of NO contacts
Type designation
Contact Lifetime output contacts DC
10000
1000
100
DC 1: 24V
DC 14: 24V
DC 13: 24V
10
1
5
Switching Current (A) →
10 16
Contact Lifetime output contacts AC
10000
1000
100
AC 3: 230V
AC 1: 400V
AC 1: 230V
AC 3: 400V
AC 15: 230V
10
1
5
Switching Current (A) →
UL 508: A600 / R150
Maximal contact load at AC 1 with 230 V:
2 contacts with 16 A each
3 contacts with 12 A each
4 contacts with 10 A each
10 16
Load Limit Curve with Direct Current
16
8
4
2
1
1
2
0,8
0,4
0,2
0,1
0 50 100 150 200 250
Voltage (VDC) →
1) Inductive load L/R 40 ms
2) Resistive load
Excitation Voltage Range
3,0
2,5
2,0
1,5
1
1,0
2
0,5
UB
UN 0
0
20
40
60
Ambient Temperature °C →
80 100
1) Max. excitation voltage with contact load:
control contacts ≤4 A, output contacts ≤12 A
2) Min. excitation voltage (guaranteed values) without
previous operation
ELESTA GmbH, Heuteilstrasse 18, Fon:
CH - 7310 Bad Ragaz, Switzerland Fax:
+41 (0)81 303 54 00
+41 (0)81 303 54 01
© Copyright
11/2014