English
Language : 

XLR Datasheet, PDF (1/2 Pages) Electronic devices inc. – HIGH VOLTAGE RECOVERY FOR X-RAY AND INDUSTRIAL APPLICATIONS STANDARD AND FAST RECOVERY TYPES
XL XLR XLU XMR XMU
HIGH VOLTAGE RECOVERY
FOR X-RAY AND
INDUSTRIAL APPLICATIONS
STANDARD AND FAST RECOVERY TYPES
EPOXY MOLDED PACKAGE
PLATINUM DOPED
AVALANCHE CAPABILITY
X-RAY BOARD ASSEMBLIES
ALSO A VAILABLE. INQUIRE.
ELECTRICAL CHARACTERISTICS (at TA=25 oC Unless Otherwise Specified)
Type
Peak Reverse Voltage, Operating,
VR(OPER)
XLR XL XLR XLU XLR XMR XMU XMU
5 10 10 12 20
5
5 10
5
9 9 11 18
5
5 9 kV
Peak Reverse Voltage, Test, V R(TEST)
5.5 10 10 12 20
5.5
5.5 10 kV
Average Rectified Forward Current in
55 o C Oil (Fig. 1 )
200 220 200 100 100 500 300 300 mA
Max. Peak Surge Current, I FRM 1/2
35 20 18 15 10 100 100 100 AMPS
Cycles @ 60Hz (Non Repetitive), Fig. 2
Max. Peak Surge Current, IFRM, 10
Cycles @ 60Hz
11
6 5.5 5 2.7 25
25 25 AMPS
Max. Forward Voltage Drop, VFM @ , l F
Max. DC Reverse Current, IRM ,
@ V R(TEST) and 25 oC,
Max. DC Reverse Current, I RM ,
@ V R(TEST) and100 o C,
lF =50mA
lF=500mA lF=300mA
7 12 14 22 28
10
11 21 V
1
11 1 1
5
55
A
30 25 30 30 30
500 350 350 A
Max. Reverse Recovery Time, TRR
lF =50mA, lR =1 00mA, l RR =25mA,(Fig.4)
175
NOT
RATED
175
50 175
150
Ambient Operating Temperature
Range, TA
-55 to +125oC
Storage Temperature Range, TSTG
-55 to +150oC
75 75 ns
If operated over 10,000 v/inch in length, devices should be immersed in oil or re-encapsulated.