English
Language : 

K1G200-AD65-04 Datasheet, PDF (9/9 Pages) ebm-papst – Operating instructions
K1G200-AD65-04
Operating instructions
Overtemperature of
electronics/motor
Insufficient cooling
Ambient temperature
too high
Unacceptable
operating point
Improve cooling. Let
the device cool
down.
To reset the error
message, switch off
the mains supply
voltage for a min. of
25 s and switch it on
again.
Reduce the ambient
temperature.
Reset by reducing
control input to 0.
Correct the operating
point. Let the device
cool down.
If you have any other problems, contact ebm-papst.
5.1 Cleaning
NOTE
Damage to the device during cleaning.
Malfunction possible
→ Do not clean the device using a water jet or high-pressure
washer.
→ Do not use any cleaners containing acids,
bases or solvents.
→ Do not use any pointed or sharp-edged objects to clean.
5.2 Safety test
What has to How to test? Frequency
be tested?
Check the
Visual inspection At least every
protective
6 months
casing against
accidental
contact for
damage and to
ensure that it is
intact
Device for
Visual inspection At least every
damage
6 months
Mounting the Visual inspection At least every
connection lines
6 months
Check the
Visual inspection At least every
insulation of
6 months
the wires for
damage
Impeller for
Visual inspection At least every
wear/deposits/
6 months
corrosion and
damage
Which
measure?
Repair or
replacement of
the device
Replace device
Fasten
Replace wires
Clean or
replace impeller
Item no. 50900-5-9970 · Revision 70035 · Release 2014-06-13 · Page 9 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com