English
Language : 

ACMAXX Datasheet, PDF (72/192 Pages) ebm-papst – Compact fans for AC and DC
max. 1245 m3/h
DC diagonal module
K1G 200 225 x 225 x 80 mm
– Material: Housing made of fibreglass-reinforced PA6 plastic, seven blades made of fibre-
glass-reinforced PA6 plastic. Rotor coated in black
– Protected against reverse polarity and locking.
– Direction of air flow “V”. Direction of rotation CW, seen on rotor.
– Type of protection: IP 20 (... 02); IP 44 (... 04). Insulation class: “B”.
– Maintenance-free ball bearings.
– Control input 0-10 VDC / PWM and tach output.
– Electrical connection via connection line AWG 20, 4x brass lead tips crimped.
– Continuous operation (S1).
– Mass: 1.7 kg.
Nominal data
Type
m3/h CFM VDC VDC
A dB(A) / Watts RPM
°C
Hours
NEW K1G 200-AD65-04
1020 600,3 24 16...28 4,7 76
95 3 400 -25...+60 67 000 / 33 000
1
NEW K1G 200-AD31-02
1045 614,9 24 16...28 5,3 77
107 3 520 -25...+70 100 000 / 50 000
2
NEW K1G 200-AD49-04
1095 644,4 48 36...57 3,4 77
120 3 650 -25...+60 80 000 / 32 000
3
NEW K1G 200-AD37-02
1245 732,7 48 36...57 5,6 81
183 4 140 -25...+70 75 000 / 30 000
4
➀❶
➀➋
➀➌
➀➍
➁❶
➁➋
➁➌
➁➍
➂❶
➂➋
➂➌
➂➍
➃❶
➃➋
➃➌
➃➍
n
[RPM]
3400
3410
3410
3410
3520
3520
3520
3520
3650
3650
3650
3650
4140
4090
4060
4110
P1 I LwA
[W] [A] [dB(A)]
95 4,70 76
116 5,61 74
119 5,75 74
117 5,62 76
107 5,30 77
127 6,24 75
129 6,31 76
126 6,18 76
120 3,40 77
141 3,90 75
145 3,99 76
141 3,88 78
183 5,60 81
212 6,46 79
213 6,52 79
211 6,43 80
Air performance measured
as per: ISO 5801,
Installation category A,
without protection against
accidental contact
Suction-side noise levels:
LwA as per ISO 13347
The acoustic values given are
only valid under the measur-
ment conditions listed and
may vary depending on the
installation situation.
With any deviation to the stan-
dard setup, the specific values
have to be checked and re-
viewed once installed or fitted!
4
500
4
3
400
24
3
14
4
3
300
33
2
2
200
22
6
100
11 1
1
0
100 200 300 400 500 600
[CFM]
200 400 600 800 1000 [m3/h]
Cable assignment:
Red = UN
Yellow = 0-10 VDC
White = Speed monitoring output
Blue = GND
6
80 +1