English
Language : 

K3G200-BD64-04 Datasheet, PDF (5/9 Pages) ebm-papst – Operating instructions
K3G200-BD64-04
Operating instructions
3.2 Nominal data
Motor
M3G074-CF
Nominal voltage / VDC
Nominal voltage
range / VDC
48
36 .. 57
Type of data definition fa
Speed / min-1
4875
Power input / W
275
Current draw / A
5.8
Min. ambient temperature -25
/ °C
Max. ambient
60
temperature
/ °C
ml = Max. load · me = Max. efficiency · fa = Running at free air
cs = Customer specs · cu = Customer unit
Subject to alterations
3.3 Data according to ErP directive
Installation category
Efficiency category
Variable speed drive
Specific ratio*
* Specific ratio = 1 + pfs / 100 000 Pa
A
Static
Yes
1.01
Overall efficiency ηes / %
Efficiency grade N
Power input Pe / kW
Air flow qv / m³/h
Pressure increase total psf / Pa
Speed n / min-1
Data definition with optimum efficiency.
Actual
49.3
65.3
0.3
900
541
4760
Request Request
2013 2015
31
34
47
50
The ErP data is determined using a motor-impeller combination in a standardised
measurement configuration.
3.4 Technical features
Mass
Size
Surface of rotor
Material of impeller
Housing material
Material of support
bracket
Number of blades
Direction of air flow
Direction of rotation
Type of protection
Insulation class
Humidity class
Mounting position
Condensate discharge
holes
Operation mode
Motor bearing
2.3 kg
200 mm
Coated in black
PA plastic
PA plastic
PA plastic
7
"V"
Clockwise, seen on rotor
IP 44; Depending on installation and
position
"B"
F2-1
Any
None
S1
Ball bearing
Technical features
Motor protection
Cable exit
Product conforming
to standard
Approval
- Tach output
- Motor current limit
- Soft start
- Control input 0-10 VDC / PWM
- Overvoltage detection
Reverse polarity and locked-rotor
protection
Lateral
EN 60335-1
EAC; CCC
For cyclic speed loads, note that the rotating parts of the device
are designed for maximum one million load cycles. If you have
specific questions, contact ebm-papst for support.
3.5 Mounting data
For depth of screw, see chapter 3.1 Product drawing
; Secure the mounting screws against accidentally coming loose (e.g.
by using self-locking screws).
Strength class for
8.8
mounting screws
You can obtain additional mounting data from the product drawing if
necessary.
3.6 Transport and storage conditions
; Use the device in accordance with its protection type.
Max. permissible
ambient motor temp.
(transp./ storage)
Min. permissible
ambient motor temp.
(transp./storage)
+ 80 °C
- 40 °C
3.7 Electromagnetic compatibility
EMC interference
immunity
EMC interference
emission
Acc. to EN 61000-6-2 (industrial
environment)
Acc. to EN 55022 (Class B, household
environment)
Item no. 53019-5-9970 · ENG · Revision 82270 · Release 2014-10-21 · Page 5 / 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com