English
Language : 

RABS2_17 Datasheet, PDF (1/3 Pages) DIYI Electronic Technology Co., Ltd. – SINGLE PHASE 0.8AMP FAST GLASS PASSIVATED BRIDGE RECTIFIER
RABS2 THRU RABS10
SINGLE PHASE 0.8 AMP FAST GLASS PASSIVATED BRIDGE RECTIFIER
Features
· Glass passivated die construction
· Low forward voltage drop
· High current capability
· High surge current capability
· Designed for surface mount application
· Plastic material-UL flammability 94V-0
0.165(4.2)
0.150(3.8)
-+
0.268(6.8)
0.236(6.0)
ABS
0.010(0.25)
0.006(0.15)
0.268(6.8)
0.236(6.0)
0.181(4.6)
0.165(4.2)
Mechanical Data
· Case: SOPA-4, molded plastic ABS
· Terminals: plated leads solderable per
MIL-STD-202, Method 208
· Polarity: as marked on case
· Mounting position: Any
· Marking: type number
0.028(0.7)
0.020(0.5)
0.209(5.3)
0.189(4.8)
0.058(1.5)
0.046(1.2)
Dimensions in inches and (millimeters)
Maximum Ratings and Electrical Characteristics
Rating at 25℃ ambient temperature unless otherwise specified.
Single Phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
RMS Reverse Voltage
SYMBOL RABS2
VRRM
VRWM
VDC
VRMS
200
140
RABS4
400
280
RABS6
600
420
RABS8
800
560
RABS10 UNITS
1000
V
700
V
Average Rectified Output Current
@Tc =100℃
IF(AV)
0.8
A
Non-Repetitive Peak Forward Surge Current 8.3ms
Single half sine-wave superimposed on rated load
(JEDEC Method)
Rating for fusing (t<8.3ms)
Forward Voltage per element @IF=0.8A
Maximum Reverse Recovery Time (Note1)
Peak Reverse Current
@TA =25℃
At Rated DC Blocking Voltage @TA =125 ℃
Typical Thermal Resistance per leg
Operating and Storage Temperature Range
IFSM
I 2t
VFM
Trr
IR
RθJA
RθJL
TJ,TSTG
30
A
3.74
1.3
150
250
5.0
200
A2 s
V
500
ns
uA
62.5
25
-55to+150
℃/W
℃
Note: 1.Reverse Recovery Test Conditions:IF=0.5A,IR=1.0A,IRR=0.25A.
version:02
1 of 3
www.dyelec.com