Electrical Characteristics (@TA = +25°C, unless otherwise specified.)
Characteristic
Output Voltage (Note 12)
Line Regulation (Notes 12 & 13)
Symbol
Min
Typ
Max
VOUT
7.2
8
8.8
—
15
50
VOUT
110
-
120
-
Temperature Coefficient
VOUT/T
—
Load Regulation (Notes 12 & 14)
VOUT
—
Minimum Value of Input Voltage Required to
Maintain Line Regulation
VIN(MIN)
10
Quiescent Current
—
IQ
—
7.2
-16
-150
—
260
3,700
—
-50
-300
—
500
6,000
Power Supply Rejection Ratio
Vin/Vout
—
45
—
Notes:
12. Measured under pulsed conditions. Pulse width ≤ 300μs. Duty cycle ≤ 2%.
13. Line regulation VOUT= VOUT(@VIN=24V)– VOUT(@VIN = 18V)
VOUT= VOUT(@VIN=60V)– VOUT(@VIN = 10V)
VOUT= VOUT(@VIN=60V)– VOUT(@VIN = 12V)
14. Load regulation VOUT= VOUT(@IOUT= 20mA)– VOUT(@IOUT= 10mA)
VOUT =VOUT(@IOUT= 50mA)– VOUT(@IOUT = 0.1mA)
Unit
Test Condition
V VIN = 24V, IOUT = 15mA
VIN = 18 to 24V, IOUT = 15mA
mV VIN = 12 to 60V, IOUT = 15mA
VIN = 10 to 60V, IOUT = 15mA
mV/°C TJ = -40°C to +125°C
VIN = 24V, IOUT = 15mA
mV IOUT = 10 to 20mA, VIN = 24V
IOUT = 0.1 to 50mA, VIN = 24V
V
—
µA VIN = 12V, IOUT = 10µA
VIN = 60V, IOUT = 10µA
dB COUT = 100nF, IOUT = 15mA,
VOUT = 8V, VIN = 10 to 60V, f = 100Hz
Typical Application Circuit
VIN = 10 to 36V
Nominal 24V
ZXTR2108
VIN
VOUT
VOUT = 8V
to µC or IC
CIN
1µF 80V
COUT
10µF 16V
GND
Example of a 8V regulated supply from a nominal 24V for powering a Controller IC.
Pin Function
Pin Name
VIN
GND
VOUT
Pin Function
Input Supply
Power Ground
Voltage Output
Notes
Input voltage can vary from -0.3V to 60V with respect to GND; for VOUT regulated then 10V ≤ VIN ≤ 60V. It is
recommended to connect a 1µF capacitor to GND.
This pin should be tied to the system ground.
Outputs a regulated 8V when 10V ≤ VIN ≤ 60V. When VIN < 10V, then VOUT maximum = VIN – 1V.
The pin can be pulled high to a maximum of +13V with respect to GND, or +5V with respect to VIN,
whichever is lower. It is recommended to connect a 10µF capacitor to GND and a minimum of 10µA to be
drawn from VOUT to maintain regulation.