English
Language : 

74HC05 Datasheet, PDF (4/7 Pages) NXP Semiconductors – Hex inverter with open-drain outputs
74HC05
Switching Characteristics
Symbol
Parameter
Test
Conditions
Propagation
Figure 1
tPD
Delay AN to YN CL = 50 pF
Figure 1
tt
Transition time
CL = 50 pF
VCC
2.0V
4.5V
6.0V
2.0V
4.5V
6.0V
TA = +25°C
Min
Typ
Max
—
25
90
—
9
18
—
7
15
—
19
75
—
7
15
—
6
13
-40°C to +85°C -40°C to +125°C
Unit
Max
Max
115
125
23
27
ns
20
23
95
110
19
22
ns
16
19
Operating Characteristics (@TA = +25°C, unless otherwise specified.)
Parameter
Test Conditions
VCC = 6V
Typ
Unit
Cpd
Power dissipation
capacitance per gate
f = 1 MHz
22
pF
CI
Input Capacitance VI = VCC – or GND
4
pF
Parameter Measurement Information
VCC
2.0V to 6.0V
Inputs
VI
tr/tf
VCC
≤6ns
VM
VCC/2
TEST
tPLZ (see Notes D and E)
tPZL(see Notes D and F)
Condition
Vload
Vload
VLOAD
2 X VCC
CL
50 pF
RL
2 KΩ
V∆
10% of Vcc
Voltage Waveform
Pulse Duration
Voltage Waveform
Propagation Delay Times
Notes:
A. Includes test lead and test apparatus capacitance.
B. All pulses are supplied at pulse repetition rate ≤ 1 MHz.
C.The inputs are measured one at a time with one transition per measurement.
D. For the open drain device tPLZ and tPZL are the same as tPD.
E. tPZL is measured at VM.
F. tPLZ is measured at VOL +V∆.
D. A Thevenin equivalent load may be used in place of VCC X 2 and resistor divider.
Figure 1 Load Circuit and Voltage Waveforms
74HC05
Document number: DS35321 Rev. 3 - 2
4 of 7
www.diodes.com
January 2013
© Diodes Incorporated