English
Language : 

MUR1020CT Datasheet, PDF (1/2 Pages) Vishay Siliconix – Ultrafast Rectifier, 2 x 5 A FRED PtTM
MUR1020CT THRU MUR1060CT
GLASS PASSIVATED SUPER FAST RECTIFIER
Reverse Voltage - 200 -600 Volts Forward Current - 10.0Amperes
FEATURES
Plastic package has Underwriters Laboratory Flammability Classification 94V-0
Fast switching for high efficiency
Low forward voltage drop
Single rectifier construction
High surge capability
For use in low voltage ,high frequency inverters,
free wheeling ,and polarity protection applications
MUR1060CT
High temperature soldering guaranteed:260 C/10 seconds,
0.25"(6.35mm)from case
Component in accordance to RoHS 2002/95/EC and
WEEE 2002/96/EC
0.159(4.05)
0.138(3.50)
MECHANICAL DATA
Case: JEDEC TO -220AB molded plastic body
Terminals: Lead solderable per MIL-STD-750,method 2026
Polarity: As marked.
Mounting Position: Any
Weight: 0.08ounce, 2.24 gram
TO-220AB
0.415(10.54)
MAX
0.410(10.41)
0.390(9.91)
PIN
1 23
0.161(4.10)
0.148(3.74)
DIA
0.114(2.90)
0.102(2.60)
0.635(16.13)
0.625(15.87)
0.185(4.70)
0.175(4.44)
0.055(1.39)
0.045(1.14)
0.145(3.68)
0.135(3.43)
0.380(8.89)
0.330(8.38)
0.610(15.57)
0.571(14.50)
1.161(29.50)
1.106(28.10)
0.590(14.22)
0.516(13.10)
0.037(0.94)
0.027(0.68)
0.105(2.67)
0.095(2.41)
0.208(5.28)
0.192(4.88)
0.022(0.58)
0.014(0.35)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
(Ratings at 25 C ambient temperature unless otherwise specified ,Single phase ,half wave ,resistive or inductive
load. For capacitive load,derate by 20%.)
Maximum repetitive peak reverse voltage
Maximum RMS voltage
Maximum DC blocking voltage
Maximum average forward
rectified current(see Fig.1)
Per leg
Total device
Peak forward surge current 8.3ms single half
sine-wave superimposed on rated load
(JEDEC method)
Maximum instantaneous forward voltage
at 10.0 A(Note 1 )
Maximum instantaneous reverse T A =25 C
current at rated DC blocking
voltage(Note 1)
TA =125 C
Maximum Reverse Recovery Time (Note 2)
Symbols
VRRM
VRMS
VDC
I(AV)
IFSM
VF
IR
Trr
MUR
1020CT
200
140
200
0.975
5
Typical thermal resistance (Note 3)
R JC
Operating junction temperature range
Storage temperature range
TJ
TSTG
Notes: 1. Pulse test: 300 s pulse width,1% duty cycle
2. Reverse recovery test conditions IF=0.5A,IR=1.0A, Irr=0.5A
3. Thermal resistance from junction to case
MUR
1040CT
400
280
400
5.0
10.0
115500.0
MUR
1060CT
600
420
600
1.3
1.7
10
500
35
3.0
-40 to+150
-40 to+150
Units
Volts
Volts
Volts
Amps
Amps
Volts
uA
ns
C/W
C
C