MDS-400APB24-AA Datasheet, PDF (9/12 Pages) Delta Electronics, Inc. – Medical AC-DC Open Frame Power Supply
Medical AC-DC Open Frame Power Supply
24V/400W 3”x5” High Density MDS-400APB24 AA
Functions
Start-up Time
The time required for the output voltage to reach 90% of its set value, after the input voltage is applied.
Rise Time
The time required for the output voltage to change from 10% to 90% of its set value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 90% of its set value, after the input voltage is removed.
■Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
9
All parameters are specified at 25°C ambient unless otherwise noted.