12V / 5V 100W Dual Output / PMT-D1V100W1A□
Assembly & Installation
Mounting holes for power supply assembly onto the mounting surface.
Ⓐ The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length.
Ⓑ This surface belongs to customer’s end system or panel where the power supply is mounted.
Ⓒ Connector
Fig. 2.1 Side Mounting (Vertical)
Fig. 2.2 Base Mounting (Vertical)
Fig. 2.3 Side Mounting (Horizontal)
• PM☐-D1V100W1AA☐ / PM☐-D1V100W1AG: Use flexible cable (stranded or solid) of AWG No. 18-12. The torque at the
connector shall not exceed 13Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm.
• PM☐-D1V100W1AH: Use flexible cable (stranded or solid) of AWG No. 18. Please refer to Table 1 for the recommended
Housing and Terminal.
Table 1
Connector (Board Mounting)
Housing
Terminal
Input (JWT)
Output (JWT)
A3963WV2-5P-A
A3963WV2-7P-U
A3963H02-5P
A3963H02-7P
A3963T0P-2
Installation of Mounting Accessories
Fig. 3 Mounting Hole Locations
With reference to Fig. 3, the device should be mounted on a sturdy heat conducting surface with minimum of 4 mounting holes for base
mounting or 3 mounting holes for side mounting. Use M3 screws only.
8
All parameters are specified at 25°C ambient and AC input unless otherwise indicated.