MDS-030AAC Datasheet, PDF (7/9 Pages) Delta Electronics, Inc. – Medical AC-DC Adapter
TECHNICAL DATASHEET
Medical AC-DC Adapter
□ MDS-030AAC Series / MDS-030AAC
Functions
Start-up Time
The time required for the output voltage (Vo) to reach 90% of its set value, after the input AC voltage is applied.
Rise Time
The time required for the output voltage (Vo) to change from 10% to 90% of its steady state value.
Hold-up Time
Hold up time is the time when the AC input collapses and output voltage retains regulation for a certain period of time. The time
required for the output to reach 95% of its set value, after the input voltage is removed.
 Graph illustrating the Start-up Time, Rise Time, and Hold-up Time
Inrush Current
Inrush current is the input current that occurs when the input
voltage is first applied. For AC input voltages, the maximum
peak value of inrush current will occur during the first half cycle
of the applied AC voltage. This peak value decreases
exponentially during subsequent cycles of AC voltage.
Dynamic Response
The power supply output voltage will remain within ±3% of its
steady state value, when subjected to a dynamic load change
from 50 to 100% of its rated current.
7
All parameters are specified at 25°C ambient unless otherwise indicated.