English
Language : 

PJ-12V150WXXA Datasheet, PDF (3/13 Pages) Delta Electronics, Inc. – PJ Open Frame Power Supply
TECHNICAL DATASHEET
PJ Open Frame Power Supply
12V 150W 1 Phase / PJ-12V150W□□A
Environment
Surrounding Air Temperature
Power De-rating
Operating Humidity
Operating Altitude
Shock Test (Non-Operating)
Vibration (Operating)
Protections
Overvoltage
Overload / Overcurrent
Over Temperature
Short Circuit
Protection Against Shock
*PE: Primary Earth
Reliability Data
MTBF
Expected Cap Life Time
Safety Standards / Directives
Electrical Safety
ITE
CE
Material and Parts
Galvanic Isolation
Operating -10°C to +70°C
Storage -25°C to +75°C
Mounting Orientation A
> 50°C de-rate power by 2% / °C
< 90Vac de-rate power by 2% / V
5 to 95% RH (Non-Condensing)
0 to 5,000 Meters
IEC 60068-2-27, 196.1m/S² (20G),11ms, once along X,
Y, and Z axis
IEC 60068-2-6, 10Hz to 55Hz @ 19.6m/S² (2G); 3 min
period, 60 min per axis for all X, Y, Z direction
13.8-16.8V, Latch Mode
> 105% of rated load current, Hiccup Mode,
Non-Latching (Auto-Recovery)
Latch Mode
Hiccup Mode, Non-Latching
(Auto-Recovery when the fault is removed)
Class I with PE* connection
> 200,000 hrs. as per JEITA RCR-9102B
10 years (115Vac, 50% load @ 40°C)
TUV Bauart to EN 60950-1, UL/cUL recognized to
UL 60950-1 and CSA C22.2 No. 60950-1
(File No. E131881), CB scheme to IEC 60950-1
IEC 60950-1
In conformance with EMC Directive 2004/108/EC and
Low Voltage Directive 2006/95/EC
RoHS Directive 2011/65/EU Compliant
Input to Output 3.0KVac
Input to Ground 2.0KVac
Output to Ground 0.5KVac
3
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (November 2014, Rev. 01)