General Data
MTBF
Type of housing
Dimensions (W / H / D) + mounting rail
Weight
Climatic Data
Ambient temperature (Operating)
Ambient temperature (Storage)
Humidity
In conformance with EMC guideline 89/336/EEC and low
voltage directive 73/23/EEC
EMC (electromagnetic compatibility)
Immunity to interference according to EN 61000-6-1
 EN 61000-4-2 2)
Housing
Discharge of static electricity (ESD)
Contact discharge:
Air Discharge :
 EN 61000-4-3 1)
Housing
Electromagnetic HF field
Frequency/Field intensity:
 EN 61000-4-4 2)
Input
Fast transients (Burst):
L,N,PE :
Signal:
 EN 61000-4-5 2)
Surge voltage capacities (Surge):
Input :
Common Mode :
Differential Mode :
 EN 61000-4-6 1)
 Conducted disturbance
 EN 61000-4-11 2)
Noise emission according to EN 61000-6-3
 Emitted radio interface
 Radio interference voltage
I/O:
Frequency / Uo:
Voltage dips
> 600,000 Hrs
Plastic Enclosed
61W * 39.5H * 120L mm
0.28kg.
0 °C to 40 °C
-35 °C to + 85 °C
5% to 95% non-condensing
FCC (Title 47 Part 15 Class B), EN55022 (CISPR 22 Class B)
Level 4
8 kV
15 kV
Level 3
80Hz – 1GHz / 10V/M, with 1kHz tone/80% modulation
Level 3
2kV3)
-
Level 3
2kV3)
1kV4)
Level 3
0.15MHz - 80MHz / 10Vrms.
Self recoverable, No damage
EN55011 (EN55022) CLASS B5)
EN55011 (EN55022) CLASS B5)
EN55011 corresponds to CISPR11 / EN55022 corresponds to CISPR22 / EM 61000 corresponds to IEC 1000
1) Criterion A: Normal operating behavior within the defined
limits.
2) Criterion B: Temporary impairment to operational behavior
that is corrected by the device itself.
3) Symmetrical: Conductor to conductor.
4) Asymmetrical: Conductor to ground.
5) Class B: Area of application industry and residential
3/5
3/18/2011