English
Language : 

SB01S Datasheet, PDF (2/4 Pages) Delta Electronics, Inc. – 1W DC/DC CONVERTER, SMD-Package, High Isolation
Input Characteristics
Parameter
Model
Min.
5V Input Models
4.5
Input Voltage Range
12V Input Models
10.8
24V Input Models
21.6
5V Input Models
-0.7
Input Surge Voltage (1 sec. max.)
12V Input Models
-0.7
24V Input Models
-0.7
Reverse Polarity Input Current
---
Input Filter
All Models
Internal Power Dissipation
---
Output Characteristics
Parameter
Conditions
Min.
Output Voltage Accuracy
---
Output Voltage Balance
Dual Output, Balanced Loads
---
Line Regulation
For Vin Change of 1%
---
Load Regulation
Io=20% to 100%
Ripple & Noise (20MHz)
---
Ripple & Noise (20MHz)
Over Line, Load & Temp.
---
Ripple & Noise (20MHz)
---
Temperature Coefficient
---
Short Circuit Protection
Typ.
Max.
5
5.5
12
13.2
24
26.4
---
9
---
18
---
30
---
0.3
Internal Capacitor
---
550
Unit
VDC
A
mW
Typ.
Max.
±1.5
±4.0
±0.1
±1.0
±1.2
±1.5
See Model Selection Guide
75
100
---
150
---
15
±0.01
±0.02
0.5 Second Max.
Unit
%
%
%
mV P-P
mV P-P
mV rms
%/℃
General Characteristics
Parameter
Conditions
I/O Isolation Voltage (rated)
I/O Isolation Resistance
I/O Isolation Capacitance
Switching Frequency
MTBF (calculated)
60 Seconds
500 VDC
100KHz, 1V
MIL-HDBK-217F@25℃, Ground Benign
Moisture Sensitivity Level (MSL)
IPC/JEDEC J-STD-020D
Recommended Input Fuse
5V Input Models
500mA Slow-Blow Type
12V Input Models
200mA Slow-Blow Type
Min.
3000
10
---
50
2,000,000
Typ.
Max.
---
---
---
---
60
100
100
150
---
---
Level 3
Unit
VDC
GΩ
pF
KHz
Hours
24V Input Models
100mA Slow-Blow Type
Environmental Specifications
Parameter
Operating Temperature Range (with Derating)
Case Temperature
Storage Temperature Range
Humidity (non condensing)
Cooling
Lead Temperature (1.5mm from case for 10Sec.)
Conditions
Ambient
Min.
Max.
-40
+85
---
+90
-50
+125
---
95
Free-Air convection
---
300
Unit
℃
℃
℃
% rel. H
℃
DS_SB01S/D_07232012
E-mail: DCDC@delta.com.tw
http://www.delta.com.tw/dcdc
P2