English
Language : 

DRP024V480W1AA_14 Datasheet, PDF (2/13 Pages) Delta Electronics, Inc. – CliQ DIN Rail Power Supply
TECHNICAL DATASHEET
CliQ DIN Rail Power Supply
24V 480W 1 Phase / DRP024V480W1AA
Specifications
Input Ratings / Characteristics
Nominal Input Voltage
Input Voltage Range
Nominal Input Frequency
Input Frequency Range
DC Input Voltage Range*
Input Current
Efficiency at 100% Load
Max Inrush Current (Cold Start)
Power Factor at 100% Load
Leakage Current
*Safety approval according to IEC/EN/UL 60950-1.
Output Ratings / Characteristics
Nominal Output Voltage
Output Voltage Tolerance
Output Voltage Adjustment Range
Output Current
Output Power
Line Regulation
Load Regulation
PARD (20MHz)
Rise Time
Start-up Time
Hold-up Time
Dynamic Response (Overshoot & Undershoot O/P Voltage)
Start-up with Capacitive Loads
100-240Vac
85-264Vac
50-60Hz
47-63Hz
120-375Vdc
< 5.70A @ 115Vac, < 2.80A @ 230Vac
> 85.0% @ 115Vac, > 88.0% @ 230Vac
< 50A @ 115Vac, < 150A @ 230Vac
> 0.97 @ 115Vac, > 0.95 @ 230Vac
< 1.25mA @ 240Vac
24Vdc
± 2% (initial set point tolerance from factory)
22-28Vdc
20.0A (continuously operating at 24)
30.0A (Power Boost for 3 seconds at 24V, refer to the
details in the Functions section)
40.0A (Power Boost for 2 seconds at 24V, refer to the
details in the Functions section)
480W (continuously operating at 24V)
720W (Power Boost for 3 seconds at 24V, refer to the
details in the Functions section)
960W (Power Boost for 2 seconds at 24V, refer to the
details in the Functions section)
< 0.5% typ. (@ 85-264Vac input, 100% load)
< 1% typ. (@ 85-264Vac input, 0-100% load)
< 240mVpp
< 100ms @ nominal input (100% load)
< 1,000ms @ nominal input (100% load)
> 20ms @ 115Vac & 230Vac (100% load)
± 5% @ 0-100% load
10,000µF Max
2
All parameters are specified at 25°C ambient unless otherwise indicated.
www.DeltaPSU.com (May 2014, Rev. 03)