Output Characteristics
Parameter
Conditions
Min.
Typ.
Max.
Unit
Output Voltage Accuracy
---
±1.0
±2.0
%
Line Regulation
Vin=Min. to Max.
---
±0.2
±1.0
%
Load Regulation
Iout=Min. to Max.
---
±0.5
±1.0
%
Ripple & Noise (20MHz)
5.1VDC Output Models
Other Output Models
%VPP of
---
2.0
3.0
V
o
%VPP of
---
1.0
1.3
V
o
Minimum Load
---
10
---
%Inom.
Over Voltage Protection
Transient Response Deviation
Zener diode clamp
(Iout=100% to Iout=50%)
---
120
---
% of Vo
±3
±6
%
Temperature Coefficient
---
±0.02
---
%/℃
Overshoot
---
---
5
% Vout
Current Limitation
Foldback, auto-recovery
(long term overload condition may cause damage)
105
---
---
%Inom.
Short Circuit Protection
Hiccup mode, indefinite (automatic recovery)
General Characteristics
Parameter
I/O Isolation Voltage
Conditions
Input to Output, 60 Seconds
Min.
3000
Typ.
Max.
Unit
---
---
VACrms
I/O Isolation Resistance
Switching Frequency
500 VDC
100
---
---
MΩ
---
100
---
KHz
Hold-up Time
---
20
---
ms
MTBF (calculated)
MIL-HDBK-217F@25℃, Ground Benign
125,000
---
---
Hours
EMC Emission
Conducted and radiated
Standard
EN 55011 class B, EN 55022 class B, FCC part 15 class B
Specification Requirement
Performance
Criteria
EN61000-4-2
Air ±8KV Cont. ±4KV
B
EN61000-4-3
80~1000MHz, 10V/m 80% AM, 1KHz modulation
A
EMC Immunity according
EN61000-6-1
EN61000-4-4
EN61000-4-5
EN61000-4-6
AC port ±2KV DC, SL, TL ±2KV not less than 1
B
min.
1.2/50μS(8/20μS) AC dif. ±1KV DC ±0.5KV
B
0.15~80MHz, 10Vrms (functional earth ports
included)
B
80% AM, 1KHz modulation
EN61000-4-8
50Hz/60Hz, 30A/m
A
EN61000-4-11
30%, 10ms
B
60%, 100ms, 95%, 5000ms
C
Protection Class II
Safety Approvals
According IEC/EN 60536
cUL/UL 60950-1,IEC/EN 60950-1
UL508 approval
Input Fuse
Built-in Fuse
External Fuse (Recommended)
All Models
6A / 250VAC
3A Slow – Blow Type