8) Byte 84-91: Date code
9) Byte 95: Check sum of bytes 64-94
10) Byte 128 to 255 had been set hex 00
Digital Diagnostic Monitoring Interface
Alarm and Warning Thresholds (2-Wire Address A2h)
Address
#
Bytes
Name
Value (Dec.)
00-01
02-03
04-05
06-07
08-09
10-11
12-13
14-15
16-17
18-19
20-21
22-23
24-25
26-27
28-29
30-31
32-33
34-35
36-37
38-39
40-45
56-91
92-94
95
96-97
98-99
100-101
102-103
104-105
106-109
110
111
112-119
2 Temp High Alarm
2 Temp Low Alarm
2 Temp High Warning
2 Temp Low Warning
2 Voltage High Alarm
2 Voltage Low Alarm
2 Voltage High Warning
2 Voltage Low Warning
2 Bias High Alarm
2 Bias Low Alarm
2 Bias High Warning
2 Bias Low Warning
2 TX Power High Alarm
2 TX Power Low Alarm
2 TX Power High Warning
2 TX Power Low Warning
2 RX Power High Alarm
2 RX Power Low Alarm
2 RX Power High Warning
2 RX Power Low Warning
16 Reversed
36 External Calibration Constants
3 Reversed
1 Checksum
2 Real Time Temperature
2 Real Time Supply Voltage
2 Real Time Tx Bias Current
2 Real Time Tx Optical Power
2 Real Time Rx Received Power
4 Reserved
1 Optional Status/ Control Bits
1 Reserved
8 Optional Set of Alarm and Warning
TC (MAX.)+15
TC (MIN.)
TC (MAX.)+10
TC (MIN.)+10
Vcc+5%
Vcc-5%
Vcc+3%
Vcc-3%
IOP+10
IOP-5
IOP+7
IOP-3
P+3
P-3
P+2
P-2
P0+3
PS-2
P0+2
PS
Notes:
1) TC: Case Operating temperature
2) IOP: Operating current at room temperature. The min. setting current is 0 mA.
3) P: Operating optical power of transmitter at room temperature.
4) P0: Overload optical power of receiver
Unit
℃
Volt
mA
dBm
dBm
Note
1
2
3
4
5
6
7
11
DELTA ELECTRONICS, INC.