English
Language : 

EN61000-4-2 Datasheet, PDF (1/10 Pages) Delta Electronics, Inc. – Panel Mount Power Supply 5V 35W 1Phase
Panel Mount Power Supply 5V 35W 1Phase
Features
Model No. PMC 5V 35W 1AA
Weight: 0.18kg
Size:
98 mm X 97 mm X 38 mm (H x W x D)
Description
RoHS compliant
2 years warranty
Universal AC input
Overload protection
Efficiency> 79% Typ.
Over voltage protection
Expected life time: 10 years
Over temperature protection
Ease of wire connection to Terminals
Full aluminum casing for lightweight
and corrosion resistant handling
The new Panel Mount Power Supply is the latest offering from one of the world’s largest power supply
manufacturers and solution providers - Delta. The product range offers a nominal output voltage of 5V, a
wide temperature range from -10°C to +70°C and a highly dependable minimum holdup time. The state-of-
the-art design is made to withstand harsh industrial environments. What makes the product stands out from
the crowd is its lightweight full aluminum body design which can withstand shock and vibration according to
IEC60068-2. Delta’s Panel Mount Power Supply also offers overvoltage and overload protection. Using a
wide input voltage range design, it is compatible worldwide. The input also includes DC operating voltage
from 120-375Vdc. Best of all, this excellent design and quality does not come with a big price tag.
INPUT SPECIFICATION
Input Voltage (Nominal)
Input Voltage range
Input Frequency (Nominal)
Input Frequency range
DC Input Voltage (Nominal)
DC Input Voltage Range
Input Current
Efficiency
Inrush current (Cold Start)
Leakage Current
100 - 240Vac
85 - 264Vac
50 - 60Hz
47 - 63Hz
125 - 250Vdc
120 - 375Vdc
< 0.9A @ 115Vac, < 0.8A @ 230Vac
> 79% @ 115Vac & 230Vac
< 30A @ 115Vac, < 60A @ 230Vac
< 1mA @ 240Vac
OUTPUT SPECIFICATION
Output Voltage (Nominal)
Output Voltage Tolerance
Output Voltage Adjust Range
Line Regulation
Load Regulation
Residual Ripple (PARD), 20MHz BW
Output Current (Nominal)
Power Derating above 50°C
Rise Time
Start-Up Time
Hold-Up Time
Dynamic Response (Overshoot &
Undershoot O/P Voltage)
Startup with capacitive loads
5 Vdc
+/- 2% (Initial set point tolerance)
4.75 – 5.5 Vdc
< 0.5% Typical @ 85 to 264Vac input, 100% load
< 1% Typical @ 85 to 264Vac input, 0 to 100% load
< 70mVpp (25°C)
7.0 A
Derated Linearly 2.5% / °C
< 30 ms @ nominal input, 100% load (25°C)
< 2500 ms @ nominal input, 100% load (25°C)
> 15ms @ 115Vac, > 80ms @ 230Vac (100% load, 25°C)
+/-5% @ 0% - 100% load
6,600µF @ nominal input & nominal O/P voltage 5V (25°C)
www.DeltaPSU.com