DPS-50AP-2-A Datasheet, PDF (1/3 Pages) Delta Electronics, Inc. – Total power 50W | |||
|
50.8(W) x 30.5(H) x 101.6(L) mm
DPS-50AP-2 A
Input
Voltage range
Frequency
Efficiency
Input Current
Output
12V
Over-current
Protection
Over-temperature
Short
Over-voltage
Operating temp.
Environment
Storage temp.
Operating humidity
Storage humidity
90~264Vac auto range
47~63Hz
The average efficiency at 25%, 50%, 75% and
100% load ⥠87%
100Vac /12V/4.17A load ⤠1.5A
240Vac / 12V/4.17A load ⤠0.75A
0A to 4.17A
Auto recovery
Latch
Auto recovery
Auto recovery
0 to 50°C Full load,60°C 80% load
-20 to 70 °C
10% - 90%
10% - 95%
FEATURES
⢠Total power 50W
⢠90-264Vac auto range input
⢠High reliability: ï¼100,000 hours @ full load
and normal input (25 â)
⢠Protection: Short / Over-current / Over-voltage
/ Over-temperature
⢠CCC: 5000 meter
⢠Bulk Cap: JP Type
⢠Safety: UL/cUL, TUV, CB by Demko ,CCC
⢠EMI: CLASS B
⢠Surge: 4KV common mode
2KV differential mode
|
▷ |