English
Language : 

DPS-40AB-11 Datasheet, PDF (1/2 Pages) Delta Electronics, Inc. – Total Power 39.96W,Peak 61.2W for 5sec.
51.5 (W) x 30.5 (H) x 115 (L) mm
DPS-40AB-11
Input
Voltage Range
Frequency
Efficiency
Input Current
Output
Protection
12V
Over-current
Over-temperature
Short
Over-voltage
Operating Temp.
Environment
Storage Temp.
Operating Humidity
Storage Humidity
90~264Vac Auto Range
47~63Hz
The average efficiency at 25%, 50%, 75% and
100% load  87.6%
100Vac/12V/3.33A load 1.2A
240Vac/12V/3.33A load 0.6A
0A ~ 3.33A
Auto Recovery
Auto Recovery
Auto Recovery
Auto Recovery
0 to 40℃
(Refer the Power de-rating curve)
The PSU should turn on at -30 ℃ @ Rated Input
Voltage
-20 to 70 ℃
20% - 85%
5% - 95%
FEATURES
• Total Power 39.96W,Peak 61.2W for 5sec.
• 90-264Vac Auto Range Input
• Efficiency:Meet DoE Level VI
• High Reliability:>100,000 Hours @ 100Vac/Full Load
(25 ℃)
• Protection:Short / Over-current / Over-voltage
/Over-temperature
• Safety:CE/ FCC/ CB/ TUV-S/ TUV-GS/ UL/CUL/ CCC/
BSMI/ RCM/ KC/ KCC(MEPS)/ NRcan/ AU-MEPS/ PSE,
meet CCC tropical standard.
• EMI:CLASS B