English
Language : 

06AK2D Datasheet, PDF (1/2 Pages) Delta Electronics, Inc. – POWER ENTRY MODULE EMI FILTERS
SERIES POWER ENTRY MODULE EMI FILTERS
V
DE
INTRODUCTIONS
1. Power module incorporates an IEC connector, a fuse holder with
optional power on/off switch and voltage selector switch, plus
an EMI filter all-in-one single, easy-to-install unit.
2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock
prevents fuse removal with line plug inserted (Use only with 250V
fuse).
3. All part numbers are UL recognized, CSA certified and VDE
approved.
4. Switch electrical lifetime: 10,000 cycles.
Maximum inrush current: 70A.
SPECIFICATIONS
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15
.50
1.0
5.0
10
30
3A
30
35
40
35
35
35
6A
16
25
30
42
45
40
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
3A
10
40
45
45
45
35
6A
6
25
30
42
45
40
TYPE & RATED CURRENT
DELTA PART NO.
115VAC
RATED CURRENT
250VAC
IEC CONNECTOR
FUSE HOLDER
POWER SWITCH
VOLTAGE SELECTOR SW
ELECTRICAL SCHEMATIC
AK1
6A
6A
FIG. A
AK2
6A
6A
SP1
FIG. A
1. Single-pole UL, CSA & VDE approved
Current rating: UL & CSA-6A both at 125VAC & 250VAC;
VDE-6A at 250VAC.
2. Double-pole UL CSA & VDE approved
Current rating: UL & CSA-6A at 125VAC, 4A at 250VAC;
VDE-4A at 250VAC.
AK2D
6A
4A
AK3
6A
6A
AK3D
6A
4A
AK4
6A
6A
AK5
6A
6A
DP2
FIG. B
SP1
REAR3
FIG. A
DP2
REAR3
FIG. B
REAR3
FIG. A
FRONT4
FIG. C
3. Voltage selector SW -UL, CSA & VDE approved
Current rating: 10A at 125VAC; 5A at 250VAC.
4. Voltage selector SW -UL, CSA & VDE approved
Current rating: UL & CSA-6A both at 125VAC & 250VAC;
VDE-6A at 250VAC.
ELECTRICAL SCHEMATIC
AK1/4 WITHOUT POWER SW
F
SW
L
Cy
L
C1 R
I
L
N
E
Cy
N
G
FIG. A
F SW
L
Cy
L
C1 R
I
L
N
E
Cy
N
G
FIG. B
AK3/4 ONLY
L'
L
C2 O
A
D
N'
G'
AK3D ONLY
L'
L
C2 O
A
D
N'
G'
L
LF
I
N
E
N
G
Cy
R C1
L
Cy
FIG. C
L'
SW
L 110V
C2 O
A 220V
D
N'
110V
G' 220V
1
110V
2
3
110V 4
For transformers with two separate windings
4-1