English
Language : 

03DPCG5S Datasheet, PDF (1/4 Pages) Delta Electronics, Inc. – SWITCHING TRANSIENT FILTERS
DPSERIES SWITCHING TRANSIENT FILTERS
DVE
INTRODUCTION
Two-stage filters provide high insertion loss for both line-to-line
and line-to-ground emissions throughout the frequency range.
COMPONENTS
PART NO.
03DPCG5S
03DPCW5S
03DPDG3S
03DPDW3S
06DPCG5
06DPCW5
06DPDW3
10DPCG5
C1 (uF)
0.33
0.47
0.66
0.47
C2 (uF)
0.33
0.47
L1 (mH)
10
6.5
2.7
0.8
5
L2 (mH)
10
4.5
14
2.83
5
PART NO.
C1 (uF) C2 (pF) L1 (mH) L2 (mH) R (K)
03DPCG5B/W5B
0.47
9.8 9.8 470
06DPCG5B/W5B
12DPCG5B/W5B
4700 7.8
7.8
1.0
3.25 3.25 220
16DPGG5B/W5B/S5B
2.8 2.8
PART NO.
03DPCG5C
03DPCW5C
06DPCG5C
06DPCW5C
12DPCG5C
12DPCW5C
16DPCG5C
16DPCW5C
16DPCS5C
20DPCG5C
20DPCS5C
30DPGS5C
Cx (uF) L1 (mH) L2 (mH) Cy (pF) R (Ohm)
2.5
2.5
0.22
0.97 0.97
1.0M
0.47
0.58 0.58 4700 470K
0.33 0.65 0.65
1.0M
1.0
0.60 0.60
220K
10000
ELECTRICAL SCHEMATIC
L
L
I
N
C1
L1
E
N
G
C2 R C3
C3
L'
L
O
L2
A
D
N'
G'
R:2.2M
C3:3300pF
L
L
I
N
Cx
L1
E
N
Cy
Cx R
L2
Cy
G
XXDPXX5C
L'
L
O
A
D
N'
L
L'
L
I
C1 R
N
L1
C3
L2
C2
C4 L
O
A
E
C3
C4 D
N
N'
G
G'
06DPDW3 ONLY C3:4700pF
C4:2200pF
L
L
I
N
C1
L1
E
N
L'
R
C1
C2
L
O
L2
A
C2
D
N'
G
DPXXB
SPECIFICATIONS
1.Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.4mA (4700pF)
@ 250VAC 50Hz: 0.8mA (4700pF)
@ 115VAC 60Hz: 1.0mA (10000pF)
@ 250VAC 50Hz: 2.0mA (10000pF)
2.Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3.Operating frequency: 50/60Hz
4.Rated voltage: 115/250VAC
MINIMUM INSERTION LOSS IN dB
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
FREQUENCY-MHz
RATING
.15 .50 1.0 5.0 10 30
3A(S)
50 70 70 60 55 40
3A
60 70 70 65 55 40
6A
58 70 70 70 60 50
10A
58 70 70 70 70 30
06DPDW3
60 70 70 65 70 60
03DPCG5B/W5B
60 70 70 65 70 60
06DPCG5B/W5B
50 60 60 60 60 35
12DPCG5B/W5B
45 60 65 65 65 45
16DPGG5B/W5B/S5B 20 35 40 50 40 30
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
3A(S)
35 48 55 55 55 45
3A
36 55 60 55 55 45
6A
40 65 65 70 70 50
10A
45 65 65 70 70 50
03DPCG5B/W5B
30 45 45 45 45 25
06DPDW3
40 60 60 60 60 60
06DPCG5B/W5B
45 50 50 55 55 45
12DPCG5B/W5B
45 45 50 50 50 50
16DPGG5B/W5B/S5B 7 55 50 50 50 40
Maximum leakage current
a. 115VAC 60Hz: 0.5mH
b. 250VAC 50Hz: 1.0mH
COMMON MODE (L-G) IN 50 OHM SYSTEM
CURRENT
STYLE
FREQUENCY-MHz
RATING
.15 .50 1.0 5.0 10 30
3A
CG5C, CW5C
45 60 60 55 45 45
6A
CG5C, CW5C
30 50 60 55 50 35
12A
CG5C, CW5C
15 25 35 55 55 35
16A CG5C, CW5C, CS5C 20 35 45 60 50 35
20A
CG5C, CS5C
15 40 45 50 50 40
30A
CS5C
10 30 35 55 45 30
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
3A
CG5C, CW5C
12 45 45 45 45 45
6A
CG5C, CW5C
8 45 45 45 45 45
12A
CG5C, CW5C
12 40 40 35 35 40
16A CG5C, CW5C, CS5C 12 40 40 45 45 50
20A
CG5C, CS5C
12 45 45 40 35 50
30A
CS5C
18 45 50 40 40 40
6-1