English
Language : 

FR1AFL Datasheet, PDF (1/2 Pages) Dc Components – TECHNICAL SPECIFICATIONS OF FAST RECOVERY SURFACE MOUNT GLASS PASSIVATED RECTIFIER VOLTAGE RANGE - 50 to 1000 Volts
DC COMPONENTS CO., LTD.
R
RECTIFIER SPECIALISTS
FR1AFL
THRU
FR1MFL
TECHNICAL SPECIFICATIONS OF FAST RECOVERY SURFACE MOUNT GLASS PASSIVATED RECTIFIER
VOLTAGE RANGE - 50 to 1000 Volts
CURRENT - 1.0 Ampere
FEATURES
* ldeal for surface mounted applications
* Low leakage current
* Low profile space
* Low forward voltage drop
* High forward surge capability
* Glass passivated junction
MECHANICAL DATA
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
*Terminals: Solder plated, solderable per
MIL-STD-750, Method 2026
* Polarity: As marked
* Mounting position: Any
* Weight: 0.017 gram
SOD-123FL
.039(1.0)
.024(0.6)
.154(3.9)
.138(3.5)
.115(2.9)
.098(2.5)
.010(0.25)
.002(0.05)
.075(1.9)
.063(1.6)
.047(1.2)
.031(0.8)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 oC ambient temperature unless otherwise specified.
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.043(1.1)
.020(0.5)
Dimensions in inches and (millimeters)
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
Peak Forward Surge Current IFM(surge): 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Forward Voltage at 1.0A DC
Maximum DC Reverse Current at
Rated DC Blocking Voltage
Maximum reverse recovery time
at IF = 0.5A , IR = 1.0A , Irr = 0.25A
@TA = 25oC
@TA = 125oC
Typical thermal resistance
Operating and Storage Temperature Range
NOTES :1. Mounted on FR-4 P.C.B. with 0.9X1.5 mm copper pads areas.
SYMBOL
VRRM
VRMS
VDC
IO
FR1AFL FR1BFL FR1DFL FR1GFL FR1JFL FR1KFL FR1MFL
50
100
200
400
600
800
1000
35
70
140
280
420
560
700
50
100
200
400
600
800
1000
1.0
UNITS
Volts
Volts
Volts
Amps
IFSM
25
Amps
VF
1.3
Volts
5.0
IR
uAmps
50
trr
150
250
500
nS
RθJA
TJ, TSTG
60
-55 to + 150
0C/ W
0C