English
Language : 

NVF4-5_05 Datasheet, PDF (2/2 Pages) DB Lectro Inc – Contact load capacity up to 30A
NHG RELAYS
NVF4-5
26.5 26.5 25
Features
Miniature.
Contact load capacity up to 30A.
Suitable for automobile.
Terminal types as inserting.
Ordering Information
NVF4-5 C Z 30 b DC12V R
1
234 5
6
7
1 Part number NVF4-5
2 Contact arrangement A:1A
3 Enclosure S: Sealed type Z: Dust cover
4 Contact current 30:30A
5 Terminals b: PCB type a: plug in type
6 Coil rated voltage(V) DC:12
7 Coil transient suppression: R: with resistance
NIL: standard
Contact Data
Contact Arrangement
Contact Material
Contact Rating (resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance or Voltage drop
Operation Electrical
life
Mechanical
Coil Parameter
1A SPSTNO
AgSnO2 , AgNi
30A/14VDC
420W
75VDC
100mV (at 30A)
105
107
Max. Switching Current:30A
Item 3.12 of IEC255-7
Item 3.30 of IEC255-7
Item 3.31 of IEC255-7
Dash
Numbers
Coil voltage
VDC
Rated Max.
Coil
resistance
10%
Pick up
voltage
VDC(max)
(67%of rated
voltage )
Release
voltage
VDC(min)
(12.5% of
rated voltage)
Coil power
consumption
W
Operate
Time
ms
Release
Time
ms
012-2200
12 15.6
67
8
1.5
2.2
7
5
CAUTION: 1.The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay.
2.Pickup and release voltage are for test purposes only and are not to be used as design criteria.
NVF4-5
Operation condition
Insulation Resistance1)
Dielectric Strength 1)
Between contacts
Between contact and coil
100M min (at 500VDC)
50Hz 500V
50Hz 500V
Item 7 of IEC255-5
Item 6 of IEC255-5
Item 6 of IEC255-5
Shock resistance
147m/s2 11ms
IEC68-2-27 Test Ea
Vibration resistance
10~40Hz double amplitude 1.5mm
IEC68-2-6 Test Fc
Terminals strength
8N
IEC68-2-21 Test Ua2
Solderability
235 2 3 0.5s
IEC68-2-20 Test Ta method 1
Ambient Temperature
-40~125
Relative Humidity
85% (at 40 )
IEC68-2-3 Test Ca
Mass
30g
Note: 1). When testing, coil terminals should be connected, If coil transient suppression is installed in relay .
Qualification inspection:
Perform the qualification test as specified in the table of IEC255-19-1 and minimum sample size 24.
Dimensions
mm /inch
26.5 Max.
1.043max.
26.5 Max.
1.043max.
2.8
0.110 0.031
4.8
0.189 2-9.5
0.374 0.0.047
Dimensions
2
0.079
1.2
0.047
6.3
7.5 10.5 0.248 0.031
0.2950.413
26.5
1.043
30 85
86
87
8.5
0.335
Mounting (Bottom view)
30 85
-
86 87
+
Wiring diagram (Bottom view)
NOTES 1).Dimensions are in millimeters.
2).Inch equivalents are given for general information only.
Ningbo Huaguan Relay Corporation LTD.