English
Language : 

JMX-94F_05 Datasheet, PDF (2/3 Pages) DB Lectro Inc – Well anti-shock and anti-vibration
NHG RELAYS
JMX-94F
39 30 17.5
Features
Magnet latching relay.
Small size, light weight.
High sensitivity & reliability.
Well anti-shock and anti-vibration.
Heavy contact load.
Ordering Information
JMX-94F A Z 60 DC12V
1
2 34
5
1 Part number JMX-94F
2 Contact arrangement A:1A B:1B
3 Enclosure S: Sealed type Z: Dust cover
03001003499
4 Contact current 40:40A 60:60A 80:80A
5 Coil rated voltage(V) DC: 9,12, 24
6 Coil NIL:Singal coil:D: Double coils
Contact Data
Contact Arrangement
Contact Material
Contact Rating(resistive)
Max. Switching Power
Max. Switching Voltage
Contact Resistance & Voltage drop
Operation life
Electrical
(Rated load)
Mechanical
(No load)
Coil Parameter
1A SPSTNO , 1B SPSTNC
AgCd O
80A/250VAC 60A/250VAC
40A/250VAC
20000VA
15000VA
10000VA
300VAC
Max. Switching Current:80A
50m (at 1A/24VDC)
100mV (at rated load)
Item 3.12 of IEC255-7
Item 3.12 of IEC255-7
104
Item 3.30 of IEC255-7
106
Item 3.31 of IEC255-7
Dash
numbers
Coil
rated
voltage
VDC
Coil
resistance
10%
Switching
voltage
VDC
(50%-70% of
rated voltage)
Pulse
magnitude
ms
Coil
power
consumption
W
Operate
Time
ms
Reset
Time
ms
009-1000
9
012-1000
12
024-1000
24
81
4.5~6.3
144
6.0~8.4
60
576
12.0~16.8
009-2000
9
2 40.5
4.5~6.3
012-2000
12
2 72
6.0~8.4
60
024-2000
24
2 288
12.0~16.8
1
20
20
2
20
20
CAUTION: 1.When latching relays are installed in equipment, the latch and reset coil should not be pulsed simultaneously.
coil should not be pulsed with less than the nominal coil voltage and pulse width should be a minimum of three
times the specified operate time of the relay. If these conditions are not followed, it is possible for the relay to
be in the magnetically neutral position .
2.Switching voltage is for test purpose only and are no to be used as design criteria.